SDS

A&S Power Technology Co., Ltd.
MODEL
A&S 702040
VER
1.0
PAGE
- 8 -/17
SPEC NO.
AS-702040-500-113
File No.
2.0748
DATE
2023-04-18
Rm. 1312 A Block, Weidonglong Business Building, No. 2125 Meilong Rd., Longhua, Shenzhen, China.
Tel+86-755-2816 9348 Fax+86-755-8415 7385
2
After above measured Remaining capacity, the
capacity on standard discharge shall be measured
after standard charge.
以上测试后剩余容量,采用标准充电,并对标准放电
下的电池进行容量测试。
Recovery capacity
恢复容量90% C5
5.6.4 Long Time Storage Characteristics 长期储存性能
After about half charge after a period of storage at 25 ±2 for one year(365 days). The remaining
available capacity is 85% C5. The capacity is determined with the capacity of the by the most of
preceding three cycles.
取新生产 3 个月内的新电池,注入 50%容量, 25 ±2℃环境温度条件下,开路搁置 365 天。储存完成后,在
25 ±2℃环境温度条件下,以 0.2CmA 进行 3 次充放电,测试恢复容量( 3 次循环的最大容量):
容量恢复≥85% C5
5.7 Mechanical Performance 机械性能
Item 项目
Measuring Procedure 测试条件
Requirements 标准
Vibration test
振动测试
After standard charge, the battery is to be tested as
following conditions:
Amplitude:0.8mm
Frequency:10~55Hz(sweep:1Hz/min)
Direction: X/Y/Z axis for 90~100min. The
battery is to be tested in three mutually
perpendicular to each axis.
电池标准充电后,将电池固定在振动台上, XYZ
三个垂直方向进行实验,震动频率在 10HZ~55HZ
1Hz/min 的速度变化,振幅位移 0.8mm,往复震动
90-100min.
No fire, no explosion, no
smoking is obtained.
不起火,不爆炸,不冒烟
Drop Test
自由跌落测试
The battery fall from a height of 1m free fall into the
cement floor, from X Y Z positive and negative
direction of each direction free fall 1 time,
电池从 1 米的高度自由下落到水泥地面上, XY
Z 正反方向各自由下落 1 次,
No fire, no explosion, no
smoking is obtained.
不起火,不爆炸,不冒烟
5.8 Safety Performance 安全性能
Item 项目
Measuring Procedure 测试条件
Requirements 标准
Short-Circuit Test
短路测试
After standard charging of the battery, connect the
positive and negative electrodes of the battery with 80
± 20mΩ lead to short-circuit the battery until the
surface temperature drops by 20% or short-circuit for
24 hours 电池标准充电后, 80±20mΩ的导线短接电
池正负极,直到表面温度降低峰值 20% 或短接 24h
No explosion, no fire.
不爆炸,不起火。