cut along dotted line to remove torn outer cover R SERIES 3000 & 3002 P/N: 7283586
OWNERS MANUAL How to maintain and operate your EcoWater Systems digital demand water conditioner R EcoWater Systems Conditioner with Remote (ECR) EcoWater Systems Refiner with Remote (ERR) SERIES 3000 & 3002 Systems Tested and Certified by NSF International and WQA against NSF/ANSI Standard 44 for softener performance and the reduction of barium and radium 226/228. ERR 3000R20 & ERR 3002R30 are Tested and Certified by NSF International and WQA against NSF/ ANSI Standard 42 for chlorine taste and odor.
ECOWATER S Y S T E M Unpacking, Table of Contents S UNPACKING TABLE OF CONTENTS EcoWater Systems conditioner models R70 and R50S are shipped from the factory in two cartons. These contain resin tank/controller assembly in one carton and the brine tank, cover, skin pack of small parts needed to assemble and install the unit, and this manual. EcoWater Systems conditioners, models R20, R30 and R40 are shipped from the factory in one master carton.
ECOWATER S Y S T E M Warranty S LIMITED WARRANTY EcoWater Systems LLC Advantage Warranty Series ECR & ERR 3000 Water System Congratulations! You have just purchased the highest quality water conditioning product on the market. To register your warranty, complete the enclosed Warranty Registration Card and mail it within 30 days of purchase.
ECOWATER S Y S T E M S WATER CONDITIONING Water conditioning is the treatment of several conditions occuring in household water. The conditions treated by the unit you have purchased are: (1) Hardness, (2) Iron, (3) Sediments, (4) Barium and (5) Radium 226 and 228. These are described below: 1. HARDNESS is a term to describe the presence of calcium and magnesium minerals in water. A chemical analysis accurately measures the amount of minerals in grain weight.
ECOWATER S Y S T E M Planning Installation S FIGURE 1 -- TYPICAL INSTALLATION DRAWINGS CONDITIONED WATER bypass valve 120V, 60Hz outlet HARD WATER HARD WATER 3-- valve bypass system outlet valve transformer (supplied) inlet valve to timer OUTLET to timer OUTLET INLET INLET bypass valve #7214383 valve drain hose brine tank overflow hose CABINET MODEL TWO TANK, MODEL brine tank overflow hose valve drain floor drain 1--1/2” airgap 1--1/2” airgap floor drain Tie or wire valve dra
ECOWATER S Y S T E M Installation S 1. INSTALL BYPASS VALVE and/or COPPER TUBES a. IF INSTALLING AN ECOWATER SYSTEMS BYPASS VALVE, put lubricated o--ring seals onto both bypass valve ports (FIGURE 3B). Carefully slide the bypass valve into the softener valve and install the “C” clips. b. Slide a lubricated o--ring seal onto each of the copper tubes. Carefully insert the copper tubes into the bypass valve (FIGURE 3B), or into the softener valve (FIGURE 3 and 3A). Then install the ‘‘C’’ clips.
ECOWATER S Y S T E M Installation S 5. CONNECT INLET AND OUTLET PLUMBING 6. COLD WATER PIPE GROUNDING a. SOLDERED COPPER The house cold water pipe (metal only) is often used as a ground for the house electrical system. The 3-valve bypass type of installation, shown in FIGURE 1, will maintain ground continuity. If you use the plastic bypass, continuity is broken. To restore the ground, do either step a or b following. (1) Thoroughly clean and flux all joints.
ECOWATER S Y S T E M 8. INSTALL BRINE TANK OVERFLOW HOSE a. Connect a length of 1/2” I. D. hose to the brine tank overflow elbow and secure in place with a hose clamp. b. Run the hose to the floor drain, or other suitable drain point no higher than the drain fitting on the tank. If the tank overfills with water, the excess water flows to the drain point. 9. On Two Tank models, connect the brine tubing to the nozzle and venturi housing. 10. ADD WATER AND SALT TO THE BRINE TANK a.
ECOWATER S Y S T E M S SALT LEVEL keypad Programming the Digital Demand Faceplate Controller ↑ display keypad SELECT/EXIT keypad RECHARGE keypad ↓ keypad TANK LIGHT keypad THE FOLLOWING STEPS ARE FOR FIRST TIME SET UP ONLY. When the transformer is plugged in, a ‘‘beep’’ will sound, followed by the factory set model code display and software version for a few seconds. Then, 12:00 PM present time display. 3. SET WATER HARDNESS: The controller is 1.
ECOWATER S Y S T E M S Programming the Digital Demand Faceplate Controller 4. SET RECHARGE (REGENERATION) TIME: The controller is factory set to 2:00 AM. At this setting, the EcoWater Systems conditioner begins recharge, or regeneration, ending no later than 5:30 AM. This is a good time in most households because water is not being used. If hot water is used while the unit is regenerating, the water heater will refill with hard water.
ECOWATER S Y S T E M S Faceplate Controller, Features/Options FEATURES AND OPTIONS NORMAL SCREEN VIEWS The display will scroll through as many as 5 screens at an interval of 4 seconds each. F Soft Water Available will show a percent of available soft water and a bar graph at the bottom of the display. F Water Flow Rate shows gallons per minute (GPM) flowing through the system at that time and a moving bar graph at the bottom of the screen.
ECOWATER S Y S T E M S Faceplate Controller, Features/Options INITIATING EXTRA RECHARGES RECHARGE NOW: Press the Recharge keypad to go to the recharge menu. Move square cursor down to Start Recharge Now. Press SELECT/EXIT keypad and a recharge begins immediately. To assure an adequate supply of conditioned water, at times of unusual or unexpected high water use demand, use the RECHARGE NOW feature.
ECOWATER S Y S T E M S Faceplate Controller, Features/Options Primary Menu, continued Water Flow Rate: Enter Primary Menu. Press the (↑) or (↓) keypads until cursor is next to Water Flow Rate. Press the SELECT/EXIT (↵ ) keypad. When selected, this screen will show the water flow rate in gallons per minute (GPM) or liters per minute (LPM) with the moving bar graph at the bottom of the display. Water Used Today: Enter Primary Menu.
ECOWATER S Y S T E M S Faceplate Controller, Features/Options Primary Menu, continued Remote Status: Enter Primary Menu. Press the (↑) or (↓) keypads until cursor is next to Remote Status. Press the SELECT/EXIT ( ↵ ) keypad. The current remote status is displayed. Send E.A.S.E. Message: Enter Primary Menu. Press the (↑) or (↓) keypads until cursor is next to Send E.A.S.E. Message. Press the SELECT/EXIT (↵) keypad. The unit will automatically start sending E.A.S.E.
ECOWATER S Y S T E M Faceplate Controller, Features/Options S Advanced/Service Menu, continued Set Model: The controller is factory set to the model code, which provides the shortest recharge times and greatest water savings. For operation at higher salt efficiency levels, the alternate model code selection is required (see the product specification sheet). Do the following to change to this code, if desired.
ECOWATER S Y S T E M S Remote Monitor, Features/Options This EcoWater Systems conditioner comes with a Remote Monitor which can conveniently be placed in your home for viewing of your conditioners’ status. During normal operation, the green LED will flash at intervals of 5 seconds. If the unit requires salt, the amber LED will flash, and if the unit needs to be checked the red LED will flash.
ECOWATER S Y S T E M Service Information S REFILLING WITH SALT CLEANING THE NOZZLE AND VENTURI Remove the brine tank cover and check the salt storage level frequently. If the conditioner uses all the salt before you add more, you will get hard water. Be sure the brinewell cover is on when adding salt. NOTE: In humid areas, it is best to keep the salt storage level lower, and to refill more often. RECOMMENDED SALT: Cube, pellet, coarse solar, etc., water conditioner salt is recommended.
ECOWATER S Y S T E M Service Information S CAUTION: ALWAYS relieve water pressure in the EcoWater Systems conditioner, as follows, before removing parts from the valve or resin tank. DE--PRESSURIZE EcoWater Systems Bypass Valve PULL OUT for service 1. Put bypass valve(s) in bypass position. 2. Do Manual Advance step 1, page 20, (fill water to brine tank will depressurize the resin tank). PRESSURIZE 1. Put bypass valve(s) in service position. 2.
ECOWATER S Y S T E M Service Information S AUTOMATIC ELECTRONIC DIAGNOSTICS The faceplate computer has a self--diagnostic function for the electrical system (except input power and water meter). The computer monitors electronic components and circuits for correct operation. If a malfunction occurs, the computer attempts to self correct, displaying ADJUST VALVE in the Normal View Screen. If self correction fails, an error code appears in the faceplate display.
ECOWATER S Y S T E M S continued from page 19 Use the recharge keypad to manually advance the valve into each cycle and check correct switch operation, and observe the valve position indicator. Service Information (↵) to start a recharge. As the EcoWater Systems conditioner enters the fill cycle of regeneration, remove the brinewell cover and, using a flashlight, observe fill water entering the tank. NOTE: The position switch is closed when the plunger is depressed, open when extended. a.
ECOWATER S Y S T E M Service Information S OTHER SERVICE WATER HAS SALTY TASTE HARD WATER BYPASS (hard water ‘‘bleeds’’ into conditioned water supply). 1. Defective inlet disc, seal, or wave washer (see pages 26 and 27). 1. House water pressure low (adjust pump, if well system). 2. Partially restricted valve drain hose, top distributor, backwash flow plug, resin tank internal riser, or bottom distributor. WIRING SCHEMATIC 2. Missing or defective o--ring(s) at resin tank to valve connection.
ECOWATER S Y S T E M Dimensions/Specifications S 20” 3--13/16” 14” IN 16” 14” OUT 14” 16” IN -- OUT IN -- OUT C 36--9/16” 45--1/8” A B 32--1/2” 32” MODEL NOMINAL RESIN TANK SIZE A B C ECR 3000R20 8” DIA. X 35” 39.5” -- -- ECR 3000R30, ECR 3002R30, ERR 3000R20 10” DIA. X 35” 39.5” 39.5” 44.8” ECR 3002R40, ERR 3002R30 10” DIA. X 47” -- 51.3” 56.6” ECR 3002R50S, ECR 3002R70 12” DIA. X 54” -- 57.1” 62.
ECOWATER S Y S T E M Dimensions/Specifications S ECR 3000R20 ERR 3000R20 ECR 3000R30 ECR 3002R30 ERR 3002R30 ECR 3002R40 ECR 3002R50S ECR 3002R70 5,700 @ 1.1 16,800 @ 4.3 20,400 @ 7.5 6,700 @ 1.4 19,300 @ 5.2 23,600 @ 8.9 8,300 @ 1.6 25,000 @ 6.4 30,200 @ 11.3 8,100 @ 1.7 23,800 @ 6.4 29,200 @ 11.0 11,300 @ 2.2 33,200 @ 8.5 40,100 @ 14.8 23,000 @ 4.5 40,800 @ 9.9 47,900 @ 15.3 32,900 @ 6.2 57,600 @ 12.8 71,500 @ 19.
ECOWATER S Y S T E M Repair Parts S ECOWATER SYSTEMS CONDITIONER ASSEMBLY 43 1 42 40 41 2 14 3 39 44 9 10 11 4 5 8 12 45 38 31 7 13 6 37 32 36 14 33 35 34 19 15 29 28 20 18 21 18 16 19 20 17 27 26 23 22 22 30 46 25 24 24 23 21
ECOWATER S Y S T E M Repair Parts S ECOWATER SYSTEMS CONDITIONER ASSEMBLY KEY NO. PART NUMBER 1 7275907 2 KEY NO.
ECOWATER S Y S T E M Repair Parts S VALVE ASSEMBLY 16 15 7 6 5 17 14 12 10 8 13 11 20 9 19 16 21 4 3 2 1 11 35 22 39 23 38 36 37 24 40 50 13 14 47 30 27 41 28 42 43 44 46 26 26 29 49 48 25 45 34 51 31 32 33 18
ECOWATER S Y S T E M Repair Parts S VALVE ASSEMBLY KEY NO. PART NO. 1 7101548 --- 7123061 KEY NO. PART NO. Turbine Asm. (All models except below) 27 1148800 Fill Flow Plug, .3 Turbine Asm. (ERR 3002R30, ECR 3002R40, ECR 3002R50S, ECR 3002R70) 28 7269176 Noz., Ven. Asm. (ECR 3000R20 £) ¤ --- 7091866 Nozz., Vent. Asm. (ERR 3000R20, ECR 3000R30, ECR 3002R30, ERR 3002R30, ECR 3002R40) ¤ --- 7085247 Nozz., Vent. Asm. (ECR 3002R50S, ECR 3002R70) ¤ 29 7084607 Flow Plug, .
ECOWATER S Y S T E M S R EcoWater Systems PO Box 64420, St.