Owner`s manual
4
DIMENSIONS / SPECIFICATIONS
IN
OUT
32---1/2”
I N --- O U T
14”
20”
I N --- O U T
14”
14”
C
B
16”
16”
36---9/16”
32”
ESD 518
IN
OUT
A
ESD 2502R30
ESD 2502R39
A
B
C
MODEL NOMINAL RESIN TANK SIZE A
B
C
ESD 518
8” DIA. X 35” 3---3/8”
38---1/8”
45”
ESD 2502R30
8” DIA. X 40” 3---3/8”
41.6”
48.75”
ESD 2502R39
10” DIA. X 47” 3---3/4”
49.8”
56.6”
ESD 518 ESD 2502R30 ESD 2502R39
Rated Capacity (grains @ salt dose) 10,100 @ 2.0 lbs
21,500 @ 6.4 lbs
25,600 @ 10.7 lbs
12,200 @ 2.4 lbs
25,600 @ 7.5 lbs
30,600 @ 12.6 lbs
12,100 @ 2.4 lbs
31,700 @ 8.9 lbs
40,200 @ 15.4 lbs
Service Flow Rate (gpm) 5.0 7.8 7.0
Pressure Drop at Service Flow Rate (psi) 7 15 6
Intermittent Flow Rate (gpm) @ 15 psi ✦ 8.7 7.8 13.3
Intermittent Flow Rate (gpm) @ 30 psi ✦ 13.5 12.2 20.9
Rated Efficiency (gr / lb of salt @ min. salt dose) ◪ 5030 @ 2.0 5070 @ 2.4 5030 @ 2.4
Amount of High Capacity Resin (cu ft) .67 .79 1.13
Water Supply Max. Hardness (gpg) 50 60 80
Water Supply Max. Clear Water Iron (ppm) ◓ 3 4 5
Water Pressure Limits (min./max. psi) ◮ 20 -- 125
Min./Max. Water Temperature (˚F) 40_ -- 120_
Min. Water Supply Flow Rate (gpm) 3
Max. Drain Flow Rate (gpm) 2.0 2.0 2.3
These systems conform to NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data.
✦ Intermittent flow rate does not represent the maximum service flow rate used for determining the softeners rated capacity and efficien-
cy. Continuous operation at flow rates greater than the maximum service flow rate may affect capacity and efficiency performance. The
validity of these flow rates is verified by NSF.
◪ Efficiency rating is only valid at the minimum stated salt dose and service flow rate. These softeners were efficiency rated according
to NSF/ANSI standard 44.
◓ Capacity to remove clear water iron is substantiated by WQA test data.
◮ Working pressure for Canadian use is 1.4 -- 7.0 kg/cm@.