Operating instructions
Table A-6 Direct Drive Blower Set-Up PSC Motor
Blower Set-Up Cooling Capacity
0.20 in. w.c. 0.50 in. w.c.
Furnace
Model
Blower
Speed Motor Speed Motor
Tons Power CFM Range
HML-60C 100-10T DD Low 1/2 HP Med-Low 1/2 HP 3 1/2 HP 690 – 1500
HML-80C 100-10T DD Med-Low 1/2 HP Med-High 1/2 HP 3 1/2 HP 690 – 1500
HML-90C 100-10T DD Med-High 1/2 HP High 1/2 HP 3 1/2 HP 690 – 1500
HML-100C 100-10T DD Med-High 1/2 HP High 1/2 HP 3 1/2 HP 690 – 1500
Table A-8 Direct Drive Blower Characteristics PSC Motor
CFM
External Static Pressure – Inches w.c.
Furnace
Model
Blower
Motor
HP
Motor
FLA
∆T
Speed
0.20 0.30 0.40 0.50 0.60
High 1741 1651 1556 1476 1369
Med-High 1557 1497 1434 1369 1278
Med-Low 1063 1051 1037 1037 1011
HML-C
60 – 100
100-10T DD 1/2 HP 7.0 60°F
Low 697 697 687 672 646
CFM RANGE
Heating Cooling
Furnace
Model
Blower
Motor
HP
Motor
FLA
∆T
Continous
Fan
0.38 - 0.48 inches
w.c.
0.5 inches w.c.
HMLV-C
60 – 100
100-10T
DD
1/2 HP
ECM
7.7 60°F 445 - 605 625 - 1500 600 - 1200
30173 Rev B 4/29/2008
13