Acclarix LX9 Series Diagnostic Ultrasound System User Manual Safety
- 4 -
Use a sterile needle with each use.
The system may be interfered with by other equipment, even if that other equipment complies
with CISPR EMISSION requirements.
The system cannot be used together with high-frequency surgical equipment.
Remove the battery from the device when the device is not used for a long time.
Transducer Warnings
To avoid infection, always use protective gloves when cleaning or disinfecting
Read and follow all manufacturer instructions for disinfection agents.
To avoid infection, ensure that expiration date of the disinfecting solution has not passed.
Disinfect the transducer after each intra-cavity or intra-operative procedure. Use a new sterile
sheath for each such procedure.
Use a pyrogen-free transducer sheath for intra-operative procedures.
The system is not intended to come into contact with the central nervous system and central
cardiovascular system.
Unplug the transducer from the system prior to cleaning or disinfecting.
Do not immerse the transducer beyond the point indicated in Figure 6-3.
Do not allow the transducer connector to get wet.
"Intra-operation" exam preset must be used when doing intra-operative examination using
transducer L17-7SQ.
2.2 Cautions
Excessive dust and dirt could clog internal airflow and cause overheating. Do not use in a
dusty environment.
Do not use a battery that leaks, emits an odor, appears deformed, or discolored. Immediately
replace it with a new Edan-supplied battery and dispose of the old battery according to local
regulations. Replace a battery that has reached the end of its service life.
Use care when storing or disposing of batteries. Do not allow the leakage from one battery to
come in contact with other batteries. Batteries (including button cell on the main board) are
hazardous waste. Do not dispose of them together with household garbage. At the end of their
life hand the batteries over to the applicable collection points for the recycling of waste
batteries. Inappropriate disposal of waste may contaminate the environment.
Inspect the system regularly, at least weekly. Before use ensure there is no visible evidence of
damage to the equipment, cables, and transducers. If a component is damaged, replace it
before use.
Do not use in locations subject to vibration.
Do not exert excessive vibrations onto the system. Otherwise, it may damage the mechanical
components (such as wheels). If the system is required to move on an uneven surface
frequently, consult EDAN or authorized representatives for service.
Read and understand the
Appendix B.2 Ultrasound Safety and the ALARA Principle
before
using the system. Do not expose a patient to ultrasound energy longer than clinically
reasonable.
Practice ALARA principle when operating ultrasound system. Minimize the acoustic power