Specifications

RK0YG302 © Danfoss 04/2007 173
Design
Connections
There is a very wide range of connection types available with ICM
valves:
D: Butt weld, DIN (2448)
A: Butt weld, ANSI (B 36.10)
J: Butt weld, JIS (B S 602)
SOC: Socket weld, ANSI (B 16.11)
SD: Solder connection, DIN (2856)
SA: Solder connection, ANSI (B 16.22)
FPT: Female pipe thread (ANSI/ASME B 1.20.1)
Approvals
The ICV valve concept is designed to full global refrigeration re-
quirements.
For specic approval information, please contact Danfoss.
The ICM valves are approved in accordance with the European
standard specied in the Pressure Equipment Directive and are CE
marked.
For further details/restrictions - see Installation Instruction.
Valve body and top cover material
Low temperature steel
Technical data
Refrigerants
Applicable to all common refrigerants including R717 and R744
(CO
2
) and non- corrosive gases/liquids.
Use with ammable hydrocarbons cannot be recommended.
Temperature range:
Media: –60/+120°C (–76/+248°F).
Pressure
The valve is designed for:
Max. working pressure: 52 bar g (754 psig)
Surface protection
ICM 20-65:
The external surface is zinc-chromated to provide good corrosion
protection.
Max. openening pressure dierential (MOPD)
– ICM 20-32: 52 bar (750 psi)
– ICM 40: 40 bar (580 psi)
– ICM 50: 30 bar (435 psi)
– ICM 65: 20 bar (290 psi)
ICM valves
Nominal bore DN ≤ 25 (1 in.) DN 32-65 mm (1
1
/
4
- 2
1
/
2
in.)
Classied for Fluid group I
Category
Article 3, para-
graph. 3
II
Additional information!
Technical brochure: DKRCI.PD.HT0.A
ICM