Specifications
RK0YG302 © Danfoss 04/2007 173
Design
Connections
There is a very wide range of connection types available with ICM
valves:
D: Butt weld, DIN (2448)
A: Butt weld, ANSI (B 36.10)
J: Butt weld, JIS (B S 602)
SOC: Socket weld, ANSI (B 16.11)
SD: Solder connection, DIN (2856)
SA: Solder connection, ANSI (B 16.22)
FPT: Female pipe thread (ANSI/ASME B 1.20.1)
Approvals
The ICV valve concept is designed to full global refrigeration re-
quirements.
For specic approval information, please contact Danfoss.
The ICM valves are approved in accordance with the European
standard specied in the Pressure Equipment Directive and are CE
marked.
For further details/restrictions - see Installation Instruction.
Valve body and top cover material
Low temperature steel
Technical data
Refrigerants
Applicable to all common refrigerants including R717 and R744
(CO
2
) and non- corrosive gases/liquids.
Use with ammable hydrocarbons cannot be recommended.
Temperature range:
Media: –60/+120°C (–76/+248°F).
Pressure
The valve is designed for:
Max. working pressure: 52 bar g (754 psig)
Surface protection
ICM 20-65:
The external surface is zinc-chromated to provide good corrosion
protection.
Max. openening pressure dierential (MOPD)
– ICM 20-32: 52 bar (750 psi)
– ICM 40: 40 bar (580 psi)
– ICM 50: 30 bar (435 psi)
– ICM 65: 20 bar (290 psi)
ICM valves
Nominal bore DN ≤ 25 (1 in.) DN 32-65 mm (1
1
/
4
- 2
1
/
2
in.)
Classied for Fluid group I
Category
Article 3, para-
graph. 3
II
Additional information!
Technical brochure: DKRCI.PD.HT0.A
ICM