Portable Air Conditioner User’s Guide 1
Catalogue Notice .......................................................................................................................03 Introduction .............................................................................................................04 Control Panel/Remote Control Panel ................................................................05 Operation Guide .....................................................................................................
Notice This manual contains important safety information on the proper use and maintenance of air conditioners to prevent personal injury or property damage. Please read the following (signs, icons) and be sure to observe the safety instructions provided. Note: This symbol indicates that personal injury or property damage may cause.
Precautions for fluorinated gas ➢ This air conditioner is a sealed unit containing fluorinated gas. For information on the specific type of gas and the quantity, please refer to the relevant label on the body. ➢ This device does not support users to add refrigerant by themselves; ➢ Maintenance or repair of this equipment must be carried out by certified technicians; Please separate this product from household waste when it is scrapped.
Design and Normative Notes ➢ Design Note: To ensure optimum performance, the design specifications and remote control of the equipment are subject to change without notice; ➢ Energy rating information: the energy rating of the machine is based on the use of an extended exhaust pipe; ➢ The batteries exemplified in this manual have to be purchased separately and the maximum operating times are measured under experimental conditions and are for reference only;This product already has a set of intake and e
Cooling mode ⚫ Default setting is cooling low air 22°C/72°F when switched on; ⚫ Press this button to enter cooling mode directly while working in other mode. Strong mode button ⚫ Press the "strong" button to put the air conditioner into strong mode, with the air conditioner working at full load. “+”button ⚫ Increase the temperature setting by 1°C per press of "+" (31°C Max), not valid in strong mode.
Battery Cell for Remote Control How to Use Can be used with the original power adapter or special batteries. Specifications of the device adapter: Input voltage: AC100-240V ~ 50-60Hz, output voltage: DC24V, power: 240 W ⚫ Power supply via adapter: ① Air conditioning power connectors ②Power adapters ③Home AC 100-240V(50-60Hz) Note: Use the adapter provided by the original manufacturer, do not use a third party adapter (to avoid unnecessary electrical hazards).
Battery removal illustration : ①Turn off the battery switch ③Rotation ②Remove the power cable ④Remove 1. Accessory connections Connecting the drain Accessory connection to the upper connection drain The unit turns gaseous water in the air into a liquid, just like a conventional air conditioner, and it uses gravity to collect and discharge the water produced. Its interior can store condensed water for approximately 1-2 hours, depending on the humidity of the air.
1. Connect the drainage hose to the drainage outlet. Place the open end of the hose directly in the drainage area of the basement or in another container. Take care that the drain hose is placed so that it does not come into contact with the power supply. Keep the hose firmly connected, free from leaks and kinks, place the end of the drain hose into the drainage area and ensure that the end of the hose is facing downwards to allow water to flow smoothly.
Battery Charging Battery charge status LED1 LED2 LED3 LED4 LED5 Power supply power ☼ ○ ○ ○ ○ 0%-20% ☀ ☼ ○ ○ ○ 20%-40% ☀ ☀ ☼ ○ ○ 40%-60% ☀ ☀ ☀ ☼ ○ 60%-80% ☀ ☀ ☀ ☀ ☀ Fully charged condition ⚫ No liability is accepted for any consequences of charging with a charger other than the one provided by the original manufacturer. ⚫ When the battery level indicator is fully illuminated, the battery is fully charged.
Operational Environment Your installation location should meet the following requirements: ⚫ Ensure that the equipment is installed on a flat surface to minimise noise and vibration. ⚫ Distance between the unit's air outlet and wall or obstruction > 30 cm and distance between the exhaust outlet and wall or obstruction > 100 cm to ensure proper space. ⚫ Do not cover the air vents, exhaust vents or sockets of the machine, as this may cause damage to the machine.
Use by Connecting Windows Use a piece of pearl cotton to fit the window, cut two 8cm diameter round holes with a hobby knife, spacing the two holes about 12cm apart, adjust the right angle and stick it to the window. Close the window and insert the two exhaust pipes of the air conditioner into the two holes. Exhaust pipe placement precautions: ⚫ To ensure proper function, do not over extend or bend the hose.
⚫ Ensure that there are no obstructions around the exhaust hose outlet (within 500mm) to allow the exhaust system to work properly. ⚫ All illustrations in this brochure are for illustration purposes only. Your air conditioner may vary slightly and the actual shape will prevail. Cold Air Extension Duct Installation Guide This accessory can be used in certain narrow spaces where it is not convenient to place the equipment, such as cabs, where it can be used to deliver cold air to the specified position.
Cleaning and Maintenance ⚫ Before cleaning and maintenance, the power must be stopped and disconnected; * Do not use flammable liquids or chemicals to clean the appliance and do not under any circumstances allow water to be used to flush the appliance as this could cause an electrical hazard; * Do not operate the machine if the power supply is damaged during the cleaning process; * Clean the casing with a soft, dry cloth or a damp cloth moistened with a neutral detergent.
Packing list Serial number 1 Photos Name Number Air conditioning mainframe 1 2 24V240W 3 80cm Adapters Drainpipes 1 1 4 Extension tubes 3 5 Cold air extension tube connectors 1 6 Extension connectors 1 7 Remote control 1 8 Instruction manual 1 15
Environmental Checklist Harmful substances Part name 六价铬 多溴联苯 (Cr+6) (PBBS) 多溴二苯醚 铅(Pb) 镉(Cd) 汞(Hg) X ○ X ○ ○ ○ X ○ ○ ○ ○ ○ X ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Rubber parts ○ ○ ○ ○ ○ ○ Power adapters X ○ ○ ○ ○ ○ Remote control ○ ○ ○ ○ ○ ○ Other plastic parts ○ ○ ○ ○ ○ ○ Compressors and accessories Pipework and valves Motors Power cables/connectors (PBDE) This form has been prepared in accordance with the provisions of SJ/T11364.