SAFETY INFORMATION = Install the dehumidifier on flat surface to minimize vibration and or noise. =» inspect the power cord before use. Never operable the dehumidifier when the power cord or plug is damaged. + inert the three-prong plug on the power cord into a matching electrically grounded outlet {(115V/ least). Da not use an adapter. Never cut off the third prong. Do not use an extension cord. = Do not operate the dehumidifier in standing water. Keep motor and wiring dry.
SPECIFICATIONS DEHUMIDIFIER Model No.: OL-R1905P Voltage & Hertz ACACIA/ 60Hz Power Consumption's Current @8O°F, 60% RH @86°F, 80% RH Refrigerant Charge (510g) Dehumidify Capacity 93Pints/Day @R0°F, 60% RH 160Pints/Day 86°F, 80% RH Maximum Design Pressure High Side: 522psig (3.6MPa) Low Side: 240psig (1.65MPa) BC 15A Compressor Input RLA: 73A LRA:364A Fan Motor Power 0.214HP CONFORMS TO UL STD. 50335-1860335-2-40 c us CERTIFIED TO CSA STD. a? Entertain £22.
DRAWINGS Fordable Handle Logo Area Air-inlet grille Quick pump access = aerie Control Panel Air Outlet Wire Nail 7 Latch Power Cord Winder Label Area Water Hose
NOTE: « Do NOT obstruct the air inlet and/or outlet while the dehumidifier is running. « Apart from the 17 ft long drain hose for pump drainage, the package also includes a 3.3 ft hose which is used for emergency drainage in the event of pump failure. OPERATION INSTRUCTIONS 1.
2. Position Your Dehumidifier {IMPORTANT Transporting or storing the dehumidifier in a horizontal position is not recommended. When the dehumidifier is placed in a horizontal position, the oil from the compressor can flow into the refrigerant coils and reduce the ability of the dehumidifier to function and possibly damage the dehumidifier, if the dehumidifier has been placed in a horizontal position, set it upright and let it stand for at least 24 hours before plugging itn.
« The drain hose for the water pump can drain up to 15ft vertically. More than 158 may cause water back up to the pump resulting in leakage. « When turning off the dehumidifier, please take the hose out from the water collection container to avoid the water back-flow causes water leakage. = To remove the drain hose from the outlet, press and hold the buckle on the connect fitting and pull the hose out. « The dehumidifier wort drain without connecting the drain hose. 4.
display screen will light up and the unit will run in Auto mode the default humidity setting data is the machine will start if the humidity condition meets the requirement of compressor operation. Press the power button again to turn off the machine, and the fan will shut down in 1 minute later. Timing Button: Press the timing button the display screen will show the current timing data, and then press Add button to increase the timing data or press Minus button to decrease the timing data.
When setting the timing data , press the button for one time to increase 1 hour , you can set the timing range from 1-24 hours ,and | hour for one step. it will cycle as below: Minus Button: Press the Minus button to decrease humidity data or decrease timing data .
Defrosting Indicator: The dehumidifier begins to defrost when the defrost indicator illuminates; the dehumidifier has stopped defrosting when the light is no longer illuminated. When defrosting is complete, the dehumidifier begins io dehumidify again automatically. Water Full Indicator: The FULL indicator lights up 1° when the pump is automatically draining the condensate from the reservoir when the reservoir is full, or (2) when the user manually drains the pump by pressing the PURGE button.
Note : when humidity of air insetting humidity data +3%RH ,and the compressor is out of 3 minutes delay start protection , the fan will start immediately and the compressor will start in 3 seconds later when humidity of air inlet scatting humidity data -3%RH , the compressor will stop working immediately Land the fan will stop working in 1 minute later §. Smart Functions Auto Drainage Thanks to the built-in pump, the dehumidifier will drain the condensation water automatically.
AUTO DRAINAGE AND MAINTENANCE AN Please disconnect the power supply before cleaning or conducting maintenance. Cleaning: Clean the unit body with a soft damp cloth. Do not submerse or place water on the unit or control panel. Water may damage the electronic components of the unit. Do not use chemical solvent such as benzene, alcohol, gasoline or other heavy-duty cleaner. The surface may become damaged or deformed. Cleaning the Air Filter: Step 1: Pull out the air filter gently.
TROUBLE SHOOTING GUIDE Trouble Possible Cause Solution Error Code: E1 | Copper head sensor failure Replace it Alr inlet temperature and humidity Error Code: E2 Replace it sensor failure Air outlet temperature and humidity Error Code: E3 Replace it sensor failure Water pump failure or Water tank of | Replace it or check Error Code: E4 water pump is full the water pump Error Code: ES | 4-way valve failure Replace it Cautions: If unit malfunctions turn off the unit and unplug it immediately.