1. Unpack the Switch and Check Contents
AS5916-54XKS
AS5916-54XL
Rack Mounting Kit—2 front-post brackets, 2 rear-post
brackets, 20 screws, and 2 ear-locking screws
Grounding kit—One grounding lug, 2 M5 screws and 2
washers (for AC model)
Grounding kit—One grounding lug, 4 ring lugs, 2 M5
screws and 2 washers (for DC model)
Power Cord
Console Cable—RJ-45 to DB-9
Documentation—Quick Start Guide (this document)
and Safety and Regulatory Information
Note:
The switch has the Open Network Install
Environment (ONIE) software installer pre-loaded on the
switch, but no switch software image. Information about
compatible switch software can be found at
www.edge-core.com.
Caution:
The switch includes plug-in power supply and fan
tray modules that are installed into its chassis. All installed
modules must have a matching airflow direction. That is, all
modules must have a front-to-back (F2B) airflow direction, or
all modules must have a back-to-front (B2F) airflow direction.
Attention:
Le commutateur comprend des modules
d'alimentation et de bac de ventilateurs installés sur son
châssis. Tous les modules installés doivent avoir une direction
de circulation d'air correspondante. C'est-à-dire que tous les
modules doivent avoir la même direction de circulation d'air :
avant vers arrière (F2B), ou arrière vers avant (B2F).
Note:
The switch drawings in this document are for
illustration only and may not match your particular switch
model.
2. Attach the Brackets
3
1
1
2
Attach each of the front- and rear-post brackets to the
switch using four of the included bracket screws.
Use an additional two screws to secure each of the rear-post
brackets at the mid-point on the sides of the switch.
Use the screws and cage nuts supplied with the rack to
secure the switch in the rack.
Caution:
Installing the switch in a rack requires two
people. One person should position the switch in the rack,
while the other secures it using the rack screws.
Attention:
Deux personnes sont nécessaires pour installer
un commutateur dans un bâti : La première personne va
positionner le commutateur dans le bâti, la seconde va le
fixer avec des vis de montage.
3. Adjust Rear-Post Bracket Ears
Lock the position of the rear-post bracket ears using the
included position-locking screws.
You can also adjust the rear-post bracket ears to fit different
rack depths from 56 cm to 75 cm.