ECIS4500 series Web Management Guide R02

142
QI
Query Interval.
The Query Interval is the interval between General Queries sent by the Querier.
The allowed range is 1 to 31744 seconds, default query interval is 125 seconds.
QRI
Query Response Interval.
The Maximum Response Delay used to calculate the Maximum Response Code
inserted into the periodic General Queries.
The allowed range is 0 to 31744 in tenths of seconds, default query response interval
is 100 in tenths of seconds (10 seconds).
LLQI
Last Listener Query Interval.
The Last Listener Query Interval is the Maximum Response Delay used to calculate
the Maximum Response Code inserted into Multicast Address Specific Queries sent
in response to Version 1 Multicast Listener Done messages. It is also the Maximum
Response Delay used to calculate the Maximum Response Code inserted into
Multicast Address and Source Specific Query messages.
The allowed range is 0 to 31744 in tenths of seconds, default last listener query
interval is 10 in tenths of seconds (1 second).
URI
Unsolicited Report Interval.
The Unsolicited Report Interval is the time between repetitions of a node's initial report
of interest in a multicast address.
The allowed range is 0 to 31744 seconds, default unsolicited report interval is 1
second.
Buttons
Refreshes the displayed table starting from the "VLAN" input
fields.
Updates the table starting from the first entry in the VLAN Table,
i.e. the entry with the lowest VLAN ID.
Updates the table, starting with the entry after the last entry
currently displayed.
Click to add new MLD VLAN. Specify the VID and configure the
new entry. Click "Save". The specific MLD VLAN starts working
after the corresponding static VLAN is also created.
Click to save changes.
Click to undo any changes made locally and revert to previously saved
values.