ECIS4500 series Web Management Guide R02

228
Buttons
Click to refresh the page immediately.
Click to refresh the page immediately.
Check this box to refresh the page automatically. Automatic refresh occurs every 3
seconds.
respective frame sizes.
Receive and Transmit Queue Counters
The number of received and transmitted packets per input and output queue.
Receive Error Counters
Rx Drops
The number of frames dropped due to lack of receive buffers or egress congestion.
Rx CRC/Alignment
The number of frames received with CRC or alignment errors.
Rx Undersize
The number of short
1
frames received with valid CRC.
Rx Oversize
The number of long
2
frames received with valid CRC.
Rx Fragments
The number of short
1
frames received with invalid CRC.
Rx Jabber
The number of long
2
frames received with invalid CRC.
Rx Filtered
The number of received frames filtered by the forwarding process.
1
Short frames are frames that are smaller than 64 bytes.
2
Long frames are frames that are longer than the configured maximum frame
length for this port.
Transmit Error Counters
Tx Drops
The number of frames dropped due to output buffer congestion.
Tx Late/Exc. Coll
The number of frames dropped due to excessive or late collisions.