CLI Reference Guide-R04

Table Of Contents
Chapter 4
| System Management Commands
System Status
– 119 –
This command displays settings for key command modes. Each mode group is
separated by “!” symbols, and includes the configuration mode command, and
corresponding commands. This command displays the following information:
MAC address for the switch
SNMP community strings
Users (names, access levels, and encrypted passwords)
VLAN database (VLAN ID, name and state)
VLAN configuration settings for each interface
Multiple spanning tree instances (name and interfaces)
IP address configured for management VLAN
Spanning tree settings
Interface settings
Any configured settings for the console port and Telnet
For security reasons, user passwords are only displayed in encrypted format.
Example
Refer to the example for the running configuration file.
Related Commands
show running-config (117)
show system This command displays system information.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
Command Usage
There are two fans in the switch that provide cooling for the internal
components. The switch also supports manual fan speed control using the
fan-speed force-full command.
There is one thermal detector in the switch, which is near the switch ASIC and
CPU.
Example
Console#show system
System Description : ECS4120-28Fv2-I
System OID String : 1.3.6.1.4.1.259.10.1.45.108
System Information
System Up Time : 0 days, 5 hours, 44 minutes, and 42.28 seconds
System Name :
System Location :
System Contact :
MAC Address (Unit 1) : A8-2B-B5-7F-E3-C0
Web Server : Enabled