CLI Reference Guide-R04

Table Of Contents
Chapter 11
| Interface Commands
Cable Diagnostics
– 439 –
Transceiver-monitor : Disabled
Transceiver-threshold-auto : Enabled
Low Alarm Low Warning High Warning High Alarm
----------- ------------ ------------ ------------ ------------
Temperature(Celsius) -25.00 -20.00 90.00 95.00
Voltage(Volts) 2.80 2.90 3.70 3.80
Current(mA) 2.00 3.00 80.00 90.00
TxPower(dBm) -7.96 -6.99 1.00 2.01
RxPower(dBm) -20.00 -19.00 0.00 1.00
Console#
Cable Diagnostics
test cable-diagnostics This command performs cable diagnostics on the specified port to diagnose any
cable faults (short, open, etc.) and report the cable length.
Syntax
test cable-diagnostics dsp interface interface
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (21-24)
Command Mode
Privileged Exec
Command Usage
Command Usage
Cable diagnostics detects per pair cable faults (accuracy 5 meters.
Interpair shorts
Intrapair shorts
Open pairs
Detects the location of cable faults.
Detects good cable (accuracy 10 meters).
Detects the length of good cables on a per pair basis
Cable diagnostics can only be performed on twisted-pair media.
This cable test is only accurate for Gigabit Ethernet cables 7 - 100 meters long.
The test takes approximately 1 second. Use the show cable-diagnostics
command to display the results of the test, including common cable failures, as
well as the status and approximate length of each cable pair.