CLI Reference Guide-R04

Table Of Contents
Chapter 11
| Interface Commands
Cable Diagnostics
– 440 –
Potential conditions which may be listed by the diagnostics include those listed
below.
Pair busy, linked partner in 100BAS-TX forced mode
Interpair short
Intrapair short
Pair open, fault detected
Invalid, cable diagnostic routine did not complete successfully
Ports must have auto-negotiation enabled
Ports are linked down while running cable diagnostics.
This cable test is only accurate for Ethernet cables 7 - 100 meters long.
Ports are linked down while running cable diagnostics.
To ensure more accurate measurement of the length to a fault, first disable
power-saving mode (using the no power-save command) on the link partner
before running cable diagnostics.
Example
Console#test cable-diagnostics dsp interface ethernet 1/21
Cable Diagnostics on interface Ethernet 1/21:
Cable OK with accuracy 10 meters.
Pair A OK, length 0 meters
Pair B OK, length 0 meters
Pair C OK, length 7 meters
Pair D Open, length 2 meters
Last Update 0n 2018-05-31 09:16:57
Console#
test loop internal
This command performs an internal loop back test on the specified port.
Syntax
test loop internal interface interface
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-28)
Command Mode
Privileged Exec