Portable Air Conditioner AP12000S-1 Owner’s Manual For more information on other great EdgeStar products on the web, go to http://www.edgestar.
Important Safety Information Improper handling can cause serious damage to the appliance and/or to the user. Please read the following safety information. Electrical Safety This unit is designed for indoor use only. Do not use the unit in extremely humid or wet environments. Do not spray water and wet the housing or control panel. Do not pull the unit by the cord. Always turn the unit off and unplug it from the outlet when cleaning.
Table of Contents IMPORTANT SAFETY INFORMATION ................................................................. I INTRODUCTION ................................................................................................... 1 PARTS IDENTIFICATION ..................................................................................... 2 BACK VIEW .......................................................................................................... 2 FRONT VIEW ...........................................
Introduction Thank you for purchasing this Koldfront portable air conditioner by EdgeStar. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship. This manual contains important information regarding the proper installation, use and maintenance of your portable air conditioner.
Parts Identification Control Panel Front View Front Air Vent Handle Caster Pre-filter Back View Air Intake Exhaust Outlet CAUTION: Make sure the drain plug is firmly installed before using the unit. This will prevent leaking.
Installing the Carbon Filter Your portable air conditioner ships with a pre-filter and an activated carbon filter. The carbon filter will help remove contaminates and odors from the air. It is recommended you replace the carbon filter every two to three months, or as needed. It is necessary to clean the pre-filter periodically. Follow the steps below to install the carbon filter: CAUTION: Never operate the air conditioner without the pre-filter attached. 1. Pull the handle on the pre-filter straight up.
Window Kit Installation Instructions Preparations for installing the window kit You must vent your portable air conditioner when running in it cooling mode. Your unit includes a window exhaust kit that can be used to vent the unit out a window. Before you begin, make sure you have all the parts necessary for installation. Window Kit Parts List: NOTE: Exhaust Covers may be attached to the Grated Adapters. You may need to twist and pull apart to separate them.
Installing the grated adapter 1. Insert the round grated adapter through the back grooved side of the window kit plate with hole. 2. Secure the grated adapter by fastening the screws from flat side of the window kit plate to the holes on the grated adapter.
Installing the window plates 3. Open your window and place the window kit with grooved side facing outward on the window sill. Then, slide the window kit plate to fit the width of the window. You can use screws to secure the window kit plate from sliding. CAUTION: Secure your window by using window locks. Please contact your dealer to purchase window locks. Koldfront Portable Air Conditioner 4. Lower the window to secure the window kit in place.
Attaching the duct connectors to the exhaust hose A. B. 5. Attach the connectors to the hose: A. Extend the ends of the exhaust hose B. Thread the duct connector on by turning it clockwise until it stops. 20” 6. Roll the unit towards the window kit. Leave a space that is at least 20 inches to the wall.
Connecting the duct connector to the unit 7. Align the slots on the duct connector to the tabs and snap into the back of the unit. Connecting the duct connector to the grated adapter 8. Align the slots on the duct connector to the tabs on the grated adapter and snap in place. After you have installed the exhaust hose and window kit, you can plug in your portable air conditioner and start using it.
Notes about the Exhaust hose Your portable air conditioner is designed to exhaust condensate water that is collected from the air. This water, in either gaseous or droplet form, will be expelled out the exhaust port of the unit. Please take this into account when deciding how to vent it. 1. The exhaust hose supplied with the portable air conditioner can be extended up to 48 inches; however for maximum efficiency, use the shortest length possible. 2. Try to prevent any kinks or bends in the exhaust hose.
Control Panel Overview Indicator Lights W ATER POWER Cooling High Dehumidify M edium Fan Only Low Mode LCD Display Timer Timer Speed Power Button Timer Button Mode Button Speed Button Infrared Sensor Down Button Button Function Power Powers the unit on or off. Mode Changes between cool, dehumidify and fan modes. The indicator light will turn on next to the mode you set. Speed Sets the fan speed. The High, Medium, or Low indicator light will turn on next to the fan speed you set.
Operating the Control Panel Power Use the Power button to turn the portable air conditioner on and off. By default when you first use the power button, the unit will begin to operate in cooling mode. The unit will remember the last used mode/settings if you shut down and restart. Auto-Restart: If power to the unit is interrupted, the air conditioner will restart itself in its last used mode/settings once power is restored. The compressor will restart after 3 minutes.
Fan Only Mode NOTE: Fan Only mode does not require that the exhaust hose be attached. Speed Fan Only mode is used to circulate the air in your room. No temperature setting is needed. To operate the unit in Fan Only mode: 1) Make sure the power cord is plugged into a power outlet. 2) Press the Power button. 3) Press the Mode button until the LED indicator next to “Fan Only” lights up. 4) Press the Speed button to select the fan speed. You can choose between High, Medium and Low.
Using the Remote Control The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The functions on the remote are the same as on the control panel. Power Button Mode Button Speed Button Up and Down Buttons Timer Button NOTES: Be careful not drop the remote control. Do not place the remote control in a location exposed to direct sunlight. Button Function Power Powers the unit on or off. Mode Changes between cool, dehumidify and fan modes.
Energy Saving Guide Read and follow the guide below to get the best performance and efficiency from your portable air conditioner: Do not cover the air outlet (exhaust) while in use. Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake. Minimize the length of the exhaust hose. Make sure the exhaust hose is as straight as possible and avoid kinks or bends. Keep curtains, blinds or drapes closed during the sunniest part of the day.
Maintenance Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning. Cleaning the unit Use a soft dry cloth to wipe the body clean. If necessary, use lukewarm water to dampen a cloth to clean the unit. Use a soft bristle brush to clean between the vents.
Troubleshooting Follow the troubleshooting guide below to resolve common issues.
Troubleshooting continued Issue Possible Cause My air conditioner is not cooling at all Unit is not operating in cooling mode NOTE: If the ambient temperature is above 90°F the unit may not blow cold air. My air conditioner blows cold air, but does not lower the room temperature TIP: Run the unit before it is needed. For example, run the unit in the morning before the area gets hot, and continue to run the unit all day long in order to maintain a low temperature.
Specifications Koldfront Portable Air Conditioner Description of product Portable Air Conditioner Model AP12000S-1 Voltage/Frequency AC 115V~60Hz Input Power 1200W Current 10.
Product Warranty Warranty Period Edgestar will be responsible for: Consumer will be responsible for: 1st year All costs for repairing or replacing parts and/or unit which proves to be defective. All transportation costs in the first 90 days. All transportation costs after 90 days. Limited 2nd-3rd year (compressor only) Repairing or replacing any compressor which proves to be defective. (Labor not included) Labor and all transportation costs.
By EdgeStar Products 500 N. Capital of TX Hwy, Bldg 5 Austin, TX 78746-3448 Toll Free: 1-866-319-5473 Web: http://www.edgestar.com E-mail: service@edgestar.com Register your product, download owner’s manuals, access additional troubleshooting resources, and obtain more information on other great EdgeStar & Koldfront products on the web at: http://www.edgestar.com Product contents and specifications may change without notice. Copyright © 2012 Living Direct, Inc.