Operating Instructions and Installation Instructions

61
ENGLISH
Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the stove to function correctly.
FAILURE TO PERFORM REGULAR MAINTENANCE, at least on a SEASONAL basis, could lead to poor fun-
ctionality.
Any problems resulting from lack of maintenance will immediately void the warranty.
DAILY MAINTENANCE
Operations must be performed when the stove is off, cold and unplugged from the power
supply
Cleaning must be carried out with a vacuum cleaner. (see optional extras page 63).
The whole procedure takes up a few minutes every day.
• Open the door and remove and empty the ash pan (**).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
• Remove the combustion chamber or use the spatula to scrape it and clean out any blocked holes on all sides.
• Remove the combustion chamber (1) and scrape with a spatula. Clean any obstructions in the apertures.
• Suction the combustion chamber holder, clean the contact edges and remove the smoke caps (2).
• Clean the glass, if necessary (when cold).
Never vacuum hot ash, it can make the vacuum cleaner breakdown and puts the household rooms at risk of fire
We remind you that using the stove without cleaning the melting pot, may cause a sudden ignition gas inside the
combustion chamber with the consequent breaking of the glass