The Iris Plus Control Panel
Right adjuster wheel



panel. The display shows the power or temperature set.
Left adjuster wheel

lower than the minimum necessary to ensure cooling of the
internal pellet fire parts.
Panel 0/1 button

Panel MENU key
For switching the fire from manual to automatic operation and
vice versa, and entering time programming mode (prog).
“+” and “-” panel keys
For moving around in time programming mode (prog).
Display unit messages


operating stage






commands.
When the pellet fire is on standby, this flashes to show
the mode it will restart in and when
Operation - Before ignition
The first few times the pellet fire is ignited there may be a slight
smell of paint, which disappears rapidly.






Auger loading
If the pellet hopper empties completely, press and release the
+ and - keys together to fill the auger. IR will be displayed.
Press O/I to end.
This must be done before igniting the pellet fire again if it has
shut down due to running out of pellets.
It is normal for a few pellets to be left in the hopper, which the
auger is not able to pick up.
Ignition
Automatic ignition
Hold the 0/1 key down for two seconds with the pellet fire on
standby to start the ignition procedure. Ac appears on the
display for a few minutes (the ignition procedure does not
actually take a preset time: it is automatically shortened if the

appears after about five minutes. It is normal for a little smoke


Manual ignition
At temperatures of less than 3°C (too low for the heating element
to glow) or if the heating element is temporarily out of order, a
firelighter may be used for ignition.
Operating modes

between modes)

right wheel) and the ventilation (with the left wheel).
Automatic: set the temperature which the room is to reach;

it (P3) or maintain it (P1).
If you set a lower temperature than current room temperature,
the pellet fire operates at P1 and consumes the corresponding


depend on the type of pellet used, the normal variability associated with solid
fuels and the periodic automatic combustion chamber cleaning (which does

Switching off
Hold the 0/1 key down for two seconds while the pellet fire is
operating. The shutdown procedure starts and the word “Off”
appears on the display (for a total of 10 minutes).
During shutdown:




• DONOTUSEFLAMMABLELIQUIDSOR
AEROSOLSTOSTARTORREKINDLETHEFIRE
• DONOTUSEFLAMMABLELIQUIDSOR
AEROSOLSINTHEVICINITYOFTHIS
APPLIANCEWHENITISOPERATING
• AVOIDCONTACTWITHHOTVENTPIPE
WARNING!Important Information