Specifications

page 4
2A FUSE
AUX
2A FUSE

RS232
RS485


P/TEMP

FLOW

ROOM

SCREW
FEEDER MOTOR




THERMOCOUPLE

SMOKE

MOTOR
SMOKE SPEED
SAFETY
THERMOSTAT
Technical Specifications (Iris Plus & Little models)
IRISPLUS&LITTLEMODELS(SAFETYDEVICES)
Thermocouple: Placed at the smoke outlet to detect the temperature,
turns the pellet fire on and off and controls its operation based on
defined parameters.
Air flow sensor: Installed at the intake duct, it trips when the

smoke circuit.
Safety thermostat: Trips when the temperature inside the pellet fire is
too high. It stops pellet loading, causing the pellet fire to shut down.
IRISPLUS&LITTLEMODELS(ELECTRICALSPECIFICATIONS)
Power supply 
0/1 switch yes
Average power consumption 150 W
Power consumption during ignition 400 W
 infrared
Electronic circuit board protection 5 x 20 2 A 250 VAC fuse
IRISPLUS(TECHNICAL&HEATINGSPECIFICATIONS)
Hopper capacity 15kg
Efficiency 
Heat Output 3.4/8kW
 
Fuel consumption 0.9/2.0 kg/h
Heatable room dimensions 150m2
Weight 140kg
Smoke duct diameter (male) 80mm
Air intake duct diameter (male) 40mm
LITTLE(TECHNICAL&HEATINGSPECIFICATIONS)
Hopper capacity 15kg
Efficiency 
Heat Output 3.4/5kW
 10/30 hours
Fuel consumption 0.5/1.45 kg/h
Heatable room dimensions (min/max) 120m2
Weight 136kg
Smoke duct diameter (male) 80mm
Air intake duct diameter (male) 40mm
The heatable room dimensions are calculated on the basis


important to consider the location of the pellet fire in the room
heated.
Please note: External electrical devices may cause interference. Work
related to live parts/components, servicing and/or inspections must be
carried out by qualified staff.
Optional extras
 Remote Control (cod. N. 254160)
It is possible to buy a remote control to turn the pellet fire
