Specifications

WATER CONNECTIONS (by authorized TAC)
THE STOVE MUST NEVER BE RUN WITHOUT WATER IN THE SYSTEM.
“WATERLESS” IGNITION DAMAGES THE STOVE.
Plumbing must be carried out by qualified staff authorized to issue declarations of conformity in compliance with
Italian law No. 46/90.
Water treatment
Add antifreeze, scale inhibitors and corrosion inhibitors. If the top-up water has a hardness greater than 35°F, use
a water softener to reduce it. Refer to Italian standard UNI 8065-1989 (Water treatment in domestic heating
systems).
Practical NOTE
When connecting the outlet, inlet and drain piping (see page 4), fit suitable means to make moving the stove easy
in the future (for example, flexible piping for the first 0.5 m)
A few possible indicative system designs are shown below.
Idrofox system as unique heat source.
This layout is purely indicative. Have a plumber design and install the system
I
DROFOX system as unique heat source.
This layout is purely indicative. Have a plumber design and install the
system.
AF: Cold water
AL: Water supply
C: Filling/Topping up
GR: Filling unit
MI: Outlet to system
P: Pump (circulator)
RA: Radiators
RI: Inlet from system
S: Drain
ST: Temperature detector
TS: Boiler-Stove
V: Ball valve
VA: Automatic bleed valve
Vec: Closed expansion tank
VSP: Safety pressure valve
VST: High temperature drainage valve
I
nternal stove
com
p
onents
10