Specifications
SERVICING
After 2500 kg of pellets are consumed, the display shows the word "Services???”.
The stove does NOT stop, but announces the need for servicing by a TAC.
Regular maintenance is essential for good stove operation.
IMPORTANT: USE THE CLEANING RODS
Before carrying out any maintenance, disconnect the device from the mains power supply
DAILY CLEANING
Clean with a vacuum cleaner. The whole process only takes a few minutes a day. Use the VACUUM CLEANER
when the stove is cold.
Remove front panel and operate front and rear scrapers (parts 10 and 11 on the exploded view on p. 6-7)
Open cover.
Use scraper provided (part 6 in the exploded view on p. 6-7) to clean heat exchange tubes in the firebox.
Vacuum clean hearth and vacuum clean the space around the combustion chamber where the ash falls.
Remove combustion chamber or clean it with a scraper, and unblock any blocked holes on all sides.
Remove and empty ash pan, and vacuum clean the underlying compartment.
Vacuum clean combustion chamber compartment, clean touching edges and replace combustion chamber.
If necessary clean glass (when cold).
NEVER VACUUM CLEAN HOT ASH
IT IS ESSENTIAL TO CLEAN THE HEAT EXCHANGE PIPES
16