Specifications

Dear Sir or Madam,
thank you for choosing our Idrofox stove.
Before using your stove, please read this booklet carefully: it explains how to exploit all its features to the full in
complete safety.
For any further information or needs, contact toll-free number (from Italy)
+39 800-014142
Please remember that the 1st ignition MUST be carried out by a TAC (EdilKamin technical assistance centre
authorized according to Italian law 46/90), which inspects the installation and fills in the guarantee.
You can get a list of centres by visiting the contacts page on the EdilKamin web site www.edilkamin.com or by
calling the toll free number shown above.
The manufacturer cannot be held liable for any damage which may derive from using the stove after incorrect
installation, incorrect maintenance or misuse.
SAFETY INFORMATION
THE STOVE MUST NEVER BE RUN WITHOUT WATER IN THE SYSTEM.
“WATERLESS” IGNITION DAMAGES THE STOVE.
The stove is designed to heat water through the automatic combustion of pellets in a firebox.
The only risks which may derive from using the stove are linked with non-compliance with the installation
instructions, direct contact with live electrical parts (inside) or with the fire or hot parts, and the introduction of
foreign substances.
If components fail, the stove is fitted with safety devices which turn it off. This must be allowed to happen
without interference .
For correct operation, the stove must be installed in compliance with the instructions herein, and the
door must not be opened during operation: combustion is managed automatically so no manual
operations are needed.
Never put foreign substances in the firebox or hopper.
Do not use flammable products to clean the smoke duct.
Firebox and hopper components must only be cleaned WHEN COLD using a vacuum cleaner.
The glass must be cleaned when COLD with a special product (e.g. GlassKamin) and cloth. Do not clean when
hot.
During stove operation, the outlet pipes and door reach high temperatures.
Do not keep objects which are not able to withstand heat in the immediate vicinity of the stove.
NEVER use liquid fuels to light the stove or rekindle the embers.
Do not block ventilation openings in the room where the stove is installed or air inlets in the stove itself.
Do not get the stove wet, and do not put wet hands near electrical parts.
Do not fit reducers on the smoke outlet pipes.
The stove must be installed in a suitable place as regards fire regulations, and provided with all the facilities
(power supply and outlet) it requires for correct safe operation.
CE STANDARDS and COMPLIANCE DECLARATION
EdilKamin declares that the Idrofox stove complies with the following C.E. marking European Directives
73/23/EEC and later modification 93/68/EEC
89/336/EEC and later modifications 93/68/EEC, 92/31/EEC and 93/97 EEC
In the case of installation in Italy, refer to Italian standard UNI 10683/98 or later modifications. For the
domestic hot water and heating system, have the plumber issue a declaration according to Italian law No. 46/90.
In all other countries, check the laws and national regulations on the subject.
2