Specifications

TECHNICAL AND HEATING SPECIFICATIONS
Hopper capacity 35 kg
Overall efficiency Up to 90 %
Water efficiency Average of 79-80 %
Overall available power (min/max) 4.5/18.5 kW
Power available for water heating (min/max) 3.5/15 kW
Time between refuellings (min/max) 9/35 hours
Fuel consumption 1 / 4 kg/h
Heatable room dimensions only considering
heating by hot water and calculating 35 kcal/m3 h
80/ 360 m3
Weight (steel/ceramic) 200/225 kg
Smoke duct diameter 8 cm
ELECTRICAL SPECIFICATIONS
Power supply 230VAC +/- 10% 50 Hz
On/off switch: yes
Average power consumption 300 W
Average power consumption during ignition 400 W
Remote control frequency infrared
Protection on mains power supply 5 x 20 2A 250 VAC fuse
Electronic circuit board protection 5 x 20 2A 250 VAC fuse
The heatable room dimensions are calculated assuming the use of pellets of the type described in the note, and home
insulation which complies with Italian law No.10/91.
A LOT DEPENDS ON THE EFFICIENCY OF THE HEAT EMITTING UNITS (RADIATORS). Bear in mind that
more than 15 kW is NOT needed.
NOTES on fuel.
The Idrofox pellet stove is designed and programmed to burn pellets.
Pellets are small 6 mm diameter (approx.) fuel cylinders made from sawdust and ground waste wood pressed at high pressure without adhesives or other
foreign material. They are sold in 15 kg bags.
In order NOT to jeopardize stove operation, do NOT burn other substances. The use of other materials (including wood), which can be detected by
laboratory analyses, invalidates the guarantee.
EdilKamin has designed, tested and programmed its stoves to perform best with pellets with the following characteristics:
diameter: 6 - 7 millimetres; maximum length: 40 mm; maximum moisture content: 8 %; heat output: 4300 kcal/kg (at least)
Use of unsuitable pellets may lead to: a decrease in efficiency; operating anomalies; stoppages due to clogging, dirty glass, unburnt fuel, etc.
Remember to comply with fire safety distances
See p. 9
AUX PORT
The TAC may install a device for remote on/off operation on the electronic circuit board (the AUX port).
WIRING DIAGRAM
CONTROL PANEL
M
AINTENANCE RS232
A
U
X
SMOKE RPM
I
N T J
WATER OUTLET
TEMPERATURE DETECTOR
ITHIUM BATTER
2A FUSE
230 V AC 50 Hz +/- 10% MAINS
SMOKE EXTRACTION MOTOR
I
GNITION HEATING ELEMEN
T
120°C TM
2A FUSE
90°C TM
P 40 Pa
SCREW FEEDER MOTOR
WATER CIRCULATION PUMP
2A FUSE
5