Specifications

16
ADVICE IN THE EVENT OF PROBLEMS
DISPLAY-CONTROL PANEL/SAFETY DEVICES
PROBLEM CAUSE SOLUTIONS
display-control panel off no mains voltage make sure the power cord is
connected
check the fuse (on the power socket)
remote control not working excessive distance from insert move nearer to insert
remote control battery flat check battery and replace if necessary
outlet air not hot too much soot in heat exchanger clean heat exchanger from inside the
firebox
no flame appears (remember that it
only appears 5 minutes after
pressing the On/Off key)
the screw feeder has not been filled Fill screw feeder (see ignition
paragraph)
ignition failure build up of unburnt material in
combustion chamber
clean combustion chamber
The ignition/off does not start at the
time required
Incorrect setting:
clock
programme enabling
programme enabling for the day
Check according to instructions
The chimney pots and smoke ducts connected to solid fuel devices must be cleaned once a year (check whether there are
regulations on the subject in the country of installation). If inspection and regular cleaning are not carried out, the
probability of a chimney pot fire increases. In the event of a chimney pot fire, proceed as follows:
do not use water to extinguish;
empty the pellet hopper;
contact specialist staff after the accident before starting up again.
C
POSSIBLE CAUSES OF SHUTDOWN
Information that may appear on the display in the event of shutdown:
1) No depression: shutdown due to low pressure
2) No expulsion: shutdown due to a fault detected by the smoke exhaust motor sensor
3) No fire: shutdown due to a drop in smoke temperature
4) No start: shutdown due to incorrect smoke temperature during ignition
5) Power failure: shutdown due to power failure
6) Termoc broken: shutdown due to thermocouple failure or disconnection
7) Over temp: shutdown when the maximum smoke temperature set is exceeded.
The message is displayed until the 0/1 key on the panel is pressed
Do not restart the insert until the problem has been looked into and the cause removed.
To start the insert up again after a shutdown
, let the shutdown procedure end
(600 seconds marked by a beep) then press the 0/1 key.
Never unplug the insert while it is shutting down due to problems.
It is important to report what the panel says to the TAC (technical assistance centre).
NOTE
After 2500 kg of pellets are consumed, the display shows the word "serviceā€
The insert works, but you should contact an authorized TAC for special maintenance.