Specifications

6
TECHNICAL AND HEATING
SPECIFICATIONS
Hopper capacity 25 kg
Efficiency 90 %
Available power (min/max) 3/10 kW
Time between refuellings (min/max) 11/35 hours
Fuel consumption (min/max) 0.7/2.2 kg/h
Heatable room dimensions (min/max) 70/250 m3
Weight 150 kg
Smoke duct diameter (female) 80 mm
Air intake duct diameter (male) 40 mm
WIRING DIAGRAM
PELLET LOADING
A convenient front drawer allows easy pellet loading without
having to remove the firebox from its housing, thus making it
absolutely safe in compliance with EN 14785 standards.
ELECTRICAL SPECIFICATIONS
Power supply
230 V
AC
+/-
10%
50 Hz
Average power consumption 150 W
Power consumption during
ignition
400 W
Remote control frequency
(supplied as standard)
infrared
Protection on mains power
supply
5 x 20 2 A 250
VAC fuse
Electronic circuit board
protection
5 x 20 2 A 250
VAC fuse
SAFETY DEVICES
THERMOCOUPLE: on the smoke outlet. It
measures the smoke temperature.
It controls the ignition, operating and shutdown
stages according to the parameters set.
AIR FLOW SENSOR: on the intake duct. It
trips when the flow of combustion air is not
correct, therefore causing low pressure
problems in the smoke circuit.
SAFETY THERMOSTAT: it trips if the
temperature inside the stove is too high. It
stops pellet loading, thus causing the stove to
go out.