IGS-1005/IGS-1105P/IGS-1210P Quick Installation Guide 10-2021 / V1.
Contents I. Product Information ................................................1 I-1. Package Contents ....................................................................... 2 I-2. Hardware Interface .................................................................... 3 I-3. LED Status .................................................................................. 6 II. Installation ...............................................................8 II-1. Mounting the Switch .......................
I. Product Information The IGS-1005, IGS-1105P and IGS-1210P are designed with fanless, DIN-rail, wall-mounted hole and metal case to offer an easy plug-and-play, flexible-deployment, cost-effective, energy efficient solution for users looking to extend networks and fulfill their high bandwidth data transfer and streaming needs.
I-1.
I-2. Hardware Interface IGS-1005 Dimension: 127.5(H) x 30(W) x 83.6(D) mm 1 2 3 No.
IGS-1105P Dimension: 180(W) x 130(D) x 32(H) mm 1 2 4 No.
IGS-1210P Dimension: 210(H) x 160.6(D) x 46(W) mm 1 2 4 No.
I-3. LED Status IGS-1005 LED P1 (PWR1) P2 (PWR2) P-Fail Color Green Green Green Status On Off On Off On Description The switch is powered by PWR1 PWR1 is disconnected or failed The system is powered by PWR2 PWR2 is disconnected or failed PWR1 or PWR2 is failed.
IGS-1105P & IGS-1210P LED Color PWR1 Green P2 (PWR2) Green P3 (DC IN) Green Status On Off On Off On Description The system is powered by PWR1 PWR1 is disconnected or failed The switch is powered by PWR2 PWR2 is disconnected or failed The switch is powered by DC IN DC IN is disconnected or failed PWR1 or PWR2 is failed.
II. Installation II-1. Mounting the Switch The industrial switch can be wall-mounted or DIN-Rail mounted. Follow bellow instruction for DIN-Rail mounting. 1. Attach the DIN-rail mounting bracket to the switch. 2. Follow the steps below to mount the switch on the DIN-Rail track.
STEP1. Insert the upper end of the DIN-Rail mounting bracket into the DIN-Rail track from its upper side. STEP2. Lightly push the bottom of the DIN-Rail mounting bracket into the track. STEP3. Check if the DIN-Rail mounting bracket is tightly attached to the track. II-2. Powering the Switch Connect the power source (sold separately) to the switch. Connect the power adapter to the DC-jack or connect a DIN-Rail power source to the power terminal block.
II-2-2. Wiring P-Fail Alarm Device: Insert the wires (no electrical polarity) into the “P-Fail” terminal block (Fault Alarm Relay). Tighten the screws to prevent the wires from loosening. Whenever the “P-Fail” is triggered, it means one of the power supplies is disconnected or failed. II-2-3. DC Power Input: DC Power Input: For IGS-1105P and IGS-1210P ONLY. DC IN: 48-55VDC, 2A or above NOTE: AC to DC power adaptor NOT included. P-Fail won’t be triggered when “DC IN” is disconnected or failed.
II-3. Connecting to Network Devices Connect the switch to end nodes using a standard Cat5e Ethernet cable as shown in the illustration below and check the LEDs to confirm the connections are established. The installation procedures have been completed.
COPYRIGHT Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission from Edimax Technology Co., Ltd. Edimax Technology Co., Ltd.
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
EU Declaration of Conformity English: This equipment is in compliance with the essential requirements and other relevant provisions of Directive 2014/30/EU. Français: Cet équipement est conforme aux exigences essentielles et autres dispositions de la directive 2014/30/EU. Čeština: Toto zařízení je v souladu se základními požadavky a ostatními příslušnými ustanoveními směrnic 2014/30/EU. Polski: Urządzenie jest zgodne z ogólnymi wymaganiami oraz szczególnymi warunkami określonymi Dyrektywą UE 2014/30/EU.
Declaration of Conformity We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the equipment described below complies with the requirements of the European R&TTE directives. Equipment: Industrial 5-Port Gigabit Din-Rail Switch (IGS-1005) Industrial 5-Port Gigabit PoE+ Din-Rail Switch with 1 SFP (IGS-1105P) Industrial 10-Port Gigabit PoE+ Din-Rail Switch with 2 SFP (IGS-1210P) Model No.
Declaration of Conformity We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the equipment described below complies with the requirements of the United Kingdom EMC and Safety directives. Equipment: Industrial 5-Port Gigabit Din-Rail Switch (IGS-1005) Industrial 5-Port Gigabit PoE+ Din-Rail Switch with 1 SFP (IGS-1105P) Industrial 10-Port Gigabit PoE+ Din-Rail Switch with 2 SFP (IGS-1210P) Model No.