User Manual
6
Mechanical
Input Power
DC 48~57V, Dual Redundant
Digital Input
1x isolated input from the electronics.
+13 to +30V for state "1"
-30 to +3V for state "0"
Max. input current: 8mA
Power Connection
1 removable 4-contact terminal block
Dimension (H*W*D)
72.2 x 145 x 113 mm
Weight
0.75KG
LED
Per unit: PWR1, PWR2, Fault, Ring Master,
Ring State
Ports: Link/Active with highest speed
(Green), low speed (Amber)
PoE: Output Power
Button
1 mulltiple function reset button
Operating Temperature
-40 to 75°C
Storage Temperature
-40 ~ 85°C
Operating Humidity
5~95% (non-condensing)
Installation
DIN-Rail mounting or optional wall mounting
MTBF
>100,000 Hours
Industrial Standard
Alarm Contact
1 relay output with current carrying capacity
of 1A @ 24 VDC
Reverse Polarity Protection
Overload Current Protection
Casing
IP30 protection, aluminum alloy case
EMI
FCC Part 15 Subpart B Class A, CE EN 55032
Class A
EMS
IEC61000-4-2 (ESD), IEC61000-4-3 (RS),
IEC61000-4-4 (EFT), IEC61000-4-5 (Surge),
IEC61000-4-6 (CS), IEC61000-4-8 (Magnetic
Field)
Shock
IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6
Green
RoHS Compliant
Certification
61000-6-2, 61000-6-4
Standard
IEEE 802.3 – 10BaseT
IEEE 802.3u – 100BaseTX
IEEE 802.3ab – 1000BaseT
IEEE 802.3z 1000BaseSX/LX
IEEE 802.3af Power over Ethernet (PoE)
IEEE 802.3at Power over Ethernet (PoE+)