8. Double-Secure Power Input Fault Alarm
The power inputs are designed as a "common negative", which
implies that the negative input is connected, but "double-secure" is
supported to prevent the un-notified failure of power from one of
the negative inputs. If one of the negative power input fails, the
system will detect it and the system will trigger the event if the users
set the fault alarm or event log for powers.
9. Console Connection
The Console port is for local management by using a terminal emulator or a
computer with terminal emulation software.
˙ DB9 connector connect to computer COM port
˙ Baud rate: 115200bps
˙ 8 data bits, 1 stop bit
˙ None Priority
˙ None flow control
I-4. LED indicators:
IGS-5208, IGS-5408P, IGS-5416P
LED Color Status Description
PWR1 Green
On Power is supplied on the power input 1.
Off Power is not supplied on the power input 1.
PWR2 Green
On Power is supplied on the power input 2.
Off Power is not supplied on the power input 2.
Fault
Green
On The system boots up and in normal operation.
Off The system is powered off or during booting.
Red On The configured event of failure is triggered.
RM Green
On This device has the Ring Master.
Off The Ring Master is not on the device.
Ring Green
On The Ring protocol is enabled and works normally.
Flickering The Ring protocol is enabled, but works abnormally.
Off The Ring protocol is disabled.