User Manual
Table Of Contents
- Intended Readers
- Icons for Note, Caution, and Warning
- I. Product Overview
- I-1 . Product Brief Description
- I-2. Product Specification
- I-3. Hardware Description
- I-4. DIN-Rail Mounting
- /I-5. Console Connection
- The Console port is for local management by using a terminal emulator or a computer with terminal emulation software.
- DB9 connector connect to computer COM port
- Baud rate: 115200bps
- 8 data bits, 1 stop bit
- None Priority
- None flow control
- I-6. Connecting Cable
- II. Preparing for Management
- III. Web Management
- III-1. Web Management - Overview
- III-2. Web Management – Basic Settings
- III-3. Web Management – Redundancy
- III-4. Web Management – Management
- III-5. Web Management – L2 Switching
- III-6. Web Management – Security
- III-7. Web Management – Diagnostics
- III-8. Web Management – Monitoring
- III-9. Web Management – MAC Table
- III-10. Web Management – Maintenance
- Appendix A: IP Configuration for Your PC
- Appendix B: CLI Command Reference
- Revision History
- Federal Communication Commission Interference Statement
- R&TTE Compliance Statement
28
CONFIGURE RSTP PORT INFO RMATION
•
No.
Port1 to PortN, where N is based on the total port number.
•
Path Cost
The cost from the current node to another device.
The range of Path Cost is from 0 to 200000000.
The default Path Cost is 0. This implies that the Path Cost is decided by the system.
•
Port Priority
Used to decide the port to be blocked in the Ring topology.
The range of Root Priority is from 0 to 240 and are in multiple of 16.
The default Root Priority is 128.
•
Admin P2P
The Admin P2P is the link-type for each port.
P2P: It is a full-duplex link.
Shared: It is a half-duplex link.
•
Edge
A port that can connect to a non-STP device is called an Edge port. Users can manually fix a port to
non-Edge or Edge.
Auto: The system automatically identifies an Edge or Non-Edge.
Edge: The port is forced to be an Edge port. An edge port will directly be transitioned to the
"Forwarding" state and is not required to wait for the "Forward Delay". If a port is directly connected
to a non-STP device, users can manually set it to "Edge" and enable it to transmit faster.
Non-Edge: The port is forced to be a Non-Edge port. This implies that the port will go through
Learning/Listening to Forwarding state even though it is connected to an end device or not.
•
Admin STP
"Enable" or "Disable" the Spanning-tree protocol that is running on the specific port.
•
(Apply Button)
After configuring above fields, click "Apply" button to make the changes effective.