CONFIGURE POE KEEP ALIVE
No.
Port1 to PortN, where N is based on the total PoE port number.
Detect
“Enable” or “Disable” to detect the Powered Device (PD) on the specific port. When the detection is
enabled, the system pings the configured IP Address on every Ping Interval.
IP Address
The field is the IP Address of the Powered Device (PD).
Ping Interval
The Ping Interval is the duration to ping the Powered Device (PD).
The range of the Ping Interval is from 1 to 65535 seconds.
The default Ping Interval is 30seconds.
Hold Time
The Hold Time is used when the ping fails. The system will wait for the Hold Time to expire and then
try to ping the PD again.
The range of the Hold Time is from 1 to 65535 seconds.
The default Hold Time is 60seconds.
(Apply Button)