User Manual
Table Of Contents
- Intended Readers
- Icons for Note, Caution, and Warning
- I. Product Overview
- I-1 . Product Brief Description
- I-2. Product Specification
- I-3. Hardware Description
- I-4. DIN-Rail Mounting
- /I-5. Console Connection
- The Console port is for local management by using a terminal emulator or a computer with terminal emulation software.
- DB9 connector connect to computer COM port
- Baud rate: 115200bps
- 8 data bits, 1 stop bit
- None Priority
- None flow control
- I-6. Connecting Cable
- II. Preparing for Management
- III. Web Management
- III-1. Web Management - Overview
- III-2. Web Management – Basic Settings
- III-3. Web Management – Redundancy
- III-4. Web Management – Management
- III-5. Web Management – L2 Switching
- III-6. Web Management – Security
- III-7. Web Management – Diagnostics
- III-8. Web Management – Monitoring
- III-9. Web Management – MAC Table
- III-10. Web Management – Maintenance
- Appendix A: IP Configuration for Your PC
- Appendix B: CLI Command Reference
- Revision History
- Federal Communication Commission Interference Statement
- R&TTE Compliance Statement
52
CONFIGURE POE PRIORITY
•
Basic Setting
。 Priority Mode
Configure the priority mode to provide the power to PDs. There are three modes: Actual, Class,
and Static.
Actual: Provide the power according to the requirement from the PD.
Class: Follow the IEEE 802.3at/af classes to provide power. For example, the PD follows class 4 so
the PSE will provide 30 Watt to it.
Static: Provide the fixed power that configured in the “Limit” fields by the user to the PDs.
。 Power Budget
This field defines the maximum power that can provide to all the connected PDs.
The range of Power Budget is from 0 to 5000 Watt.
The default Power Budget is 1600 Watt.
•
Power Settings
。 No.
Port1 to PortN, where N is based on the total PoE port number.
。 Priority
Assign the PoE priority to high, middle, or low for the specific port.
。 Limit
Set the power limitation for the specific port. The system will provide the limited watts to the PD
without detecting how many watts the PD needs. This field only works when the priority mode is
set to “Static”.
The range of Limit is from 4 to 35 Watt.
The default Limit is 35 Watt.
•
(Apply Button)
After configuring above fields, click "Apply" button to make the changes effective.