User Manual

Table Of Contents
5
Mechanical
Input Power
DC 48~57V, Dual Redundant
Power Connection
1 removable 4-contact terminal block
Digital Input
1x isolated input from the electronics.
+13 to +30V for state "1"
-30 to +3V for state "0"
Max. input current: 8mA
Dimension (H*W*D)
90.8 x 145 x 113 mm
Weight
1.4KG
LED
Per unit: PWR1, PWR2, Fault, Ring Master, Ring State
Ports: Link/Active with highest speed (Green), low speed (Amber)
PoE: Output Power
Button
1 mulltiple function reset button
Operating Temperature
-40 to 75°C
Storage Temperature
-40 ~ 85°C
Operating Humidity
5~95% (non-condensing)
Installation
DIN-Rail mounting or optional wall mounting
MTBF
>100,000 Hours
Industrial Standard
Alarm Contact
1 relay output with current carrying capacity of 1A @ 24 VDC
Reverse Polarity Protection
Overload Current Protection
Casing
IP30 protection, aluminum alloy case
EMI
FCC Part 15 Subpart B Class A, CE EN 55032 Class A
EMS
IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5
(Surge), IEC61000-4-6 (CS), IEC61000-4-8 (Magnetic Field)
Shock
IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6
Green
RoHS Compliant
Certification
61000-6-2, 61000-6-4
Standard
IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX
IEEE 802.3ab 1000BaseT
IEEE 802.3z 1000BaseSX/LX
IEEE 802.3af Power over Ethernet (PoE)
IEEE 802.3at Power over Ethernet (PoE+)
IEEE 802.3x Flow Control
IEEE 802.1Q VLAN
IEEE 802.1pClass of Service
IEEE 802.1D Spanning Tree
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1s Multiple Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.1AB LLDP (Link Layer Discovery Protocol)
IEEE 802.1XAccess Control
ITU-T G.8032/Y.1344 - Ethernet Ring Protection Switching (ERPS)