Installation Guide and Manual

17
12) FAULTS are communicated through the LCD display. The
display will switch from the SETPOINT screen to the FAULT
screen and back again every 3 seconds. FAULTS indicate an
undesirable condition and will immediately shut down the
operation of the heater. If faults are appearing on your heater
call Eemax Technical Support for assistance.
Fault Codes
F0: Outlet thermistor out of range
F1: No change in water temperature detected
F2: Dry fire detected - Optical Sensor Tripped
F3: Excessive dry fire occurrences detected
F4: Inlet thermistor out of range
13) The security of the heater settings is provided by pressing
and holding the LEFT and UP buttons for 3 seconds to lock the
buttons. Once locked, the buttons have no function. Press and
hold the same LEFT and UP buttons for 3 seconds to unlock the
buttons.
The security status can be checked at any time by pressing any
one button. If the system is locked, the screen will display
“BUTTONS LOCKED”.
[ + ] =
14) The display can be turned off or on. Press and hold the
DOWN and RIGHT buttons for 3 seconds. If the display is off, it
can be turned on by pressing and holding the same DOWN and
RIGHT buttons for 3 seconds.
+
1 ERROR
CODE1:F0
SOFTWARE
20131218
BUTTONS
LOCKED