Specification Sheet

Information and product specications contained in this document are subject to change without notice. REV 2020-01
Specications
Tankless Electric Water Heater
SpecAdvantage
For Commercial and Industrial Applications
Applications
Designed for low duty cycle applications where precise
temperature controls and low pressure drop are required
Performance Features
Designed for commercial and industrial applications
Capable of high volume and high temperature applications at
low duty cycle
Fully modulating - Predictive control algorithm and diverse safety
features ensures precise temperature control
T&P not required per UL499 (check local codes)
Thermo-Optical Sensor for infrared element monitoring
Field programmable, updatable rmware, and adjustable
Optional Features (NEMA cabinet required)
N4 (powder coated steel), N4X (304SS) N4X6 (316SS)
enclosures
Free standing legs
Freeze protection for harsh climate, up to -30°F
Non-fused or fused electrical disconnect
GFCI
Explosion proof – C1D2 Compliant, local certication required.
Class Z purge and pressurization system provided with pressure
switch for alarm controls. For classication other than C1D2
please contact the factory to discuss options.
Siren and beacon - audible and visual alarm (C1D2 compliant
when paired with explosion proof package)
Product Specications
Min. Operating Pressure: 35 PSI
Max. Operating Pressure:
150 PSI
Optimum Operating Pressure: 60-90 PSI
U.S. Patent #'s: US20140023354 and US20140178057
Installation Requirements
Properly sized water hammer arrestor
Minimum 35 PSI dynamic pressure at inlet
Sediment lter installed on inlet
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Custom orders non-refundable
Suggested Specication
Tankless water heater shall be an Eemax SpecAdvantage model
number AP_________________________.
Optional factory installation in a ____(N4/N4X/N4X6) enclosure.
Enclosure to be tted with the following features:
_____ FP
Freeze protection (-30°F)
_____ EDS Non-fused disconnect
_____ FDS Fused disconnect
_____ EP Explosion proof (C1D2 compliant)
_____ GFCI True RMS GFCI with digital display and reset
_____ SK 24" legs for free standing applications
_____ RD Remote display
_____ SB Siren and Beacon
_____ DC Dry contact
_____ ES Emergency stop - push button
Tankless water heater must have water connections on the
bottom, and be constructed with NSF 61 listed materials. Direct
heating element to be non-ferrous, cartridge style, designed for
eld replacement. Tankless water heater to utilize a dual PID
algorithm, actively managing power application to real-time system
demand. Integrated ow meter capable of volumes in excess of
30 GPM drives predictive control algorithm. Water heater must be
protected by redundant safeties. Redundant safeties to include
thermo mechanical safety switches, infrared element monitoring
via thermo optical sensors, and dual temperature monitoring via
master control board. Tankless water heater user interface must
have the following capabilities:
Selectable display including Celsius/Fahrenheit, inlet
temperature, outlet temperature, ow rate, and setpoint
temperature.
Capable of displaying ow rate in gallons per minute or liters
per minute.
Diagnostic features to include error and fault code display.
Control board must maintain error/fault history of 9 events.
Capable of factory coded temperature setting (max. and min.)
Capable of rmware upgrades via USB port
Capable of BMS integration - contact factory
Compliant with ANSI Z358.1 tepid water without additional
mixing or purge features (inlet temperatures must not exceed
100°F when selecting an EE or EFD option)
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
In USA
Assembled