SELECTING A LOCATION TO INSTALL
This product is designed to be installed indoors only. You may be able to install your unit in an outdoor
location as long as it is mounted in a suitable enclosure that protects it from rain, splashed water, direct
sunlight, debris, and insects.
DO NOT install this product in a location where it may be subject to freezing temperatures. If the water
inside your tankless water heater freezes, it can cause severe and permanent damage that is not covered
under your warranty.
DO NOT locate the water heater in a location that is difficult to access.
Make sure that the water heater and hot water outlet pipe are out of the reach of children so they cannot
tamper with the temperature controls or injure themselves by touching the hot water outlet pipe. The outlet
water pipe can get very hot.
This product does NOT require venting.
Avoid installing your tankless water heater in a location prone to excessive humidity, moisture, or dust, or in an
area where it may be splashed with water or other liquids. DO NOT install under water pipes or air conditioning lines
that might leak or condense moisture that could then drip onto the heater. DO NOT install above electrical
boxes or junctions.
If you plan to install your water heater on a second floor or in a heated attic space, make sure that you follow all
code requirements for such installations as required for your area. We recommend that you install a drip pan
(connected to a safe drain) below the water heater to avoid property damage in the unlikely event of a leak.
Alternatively, you can install an active water leak detector and shutoff valve designed to turn off your water
supply in the event that a leak is ever detected.
3-
MOUNTING YOUR WATER HEATER
Your tankless water heater should be secured to the mounting surface with 4 screws (minimum 1 inch long)
using the built-in mounting brackets on each side of the heater. Make sure that the mounting surface is solid and
secure, and ensure that the unit is level prior to securing the screws. For ease of installation and servicing, we
recommend that this product be installed in an upright position with the inlet and outlet water connections at
the bottom of the unit for the 18, 24, 27, and 36 kW models, and with the inlet and outlet water connections on the
left and right sides of the unit for the 8, 11, and 13 kW models.
Recommended Clearances:
12 inches above and below the heater
6 inches in front of and to the sides of the heater
CAUTION: Combustible materials should be kept at least 24 inches away from your water heater and the hot