Cutting the Copper Hot Water Pipe Layout A
Please follow all pre-installation instructions carefully. We recommend that this product be installed by a
qualified homeowner. If further assistance is needed, a licensed and qualified plumber in accordance with
all applicable national, state, provincial, and local plumbing codes should be hired.
1. Locate the hot water outlet connection on your pre-existing water tank. On the copper pipe, mark
with a pencil 2 inches above the topmost point of the hot water outlet connection fitting.
2. Using a pipe cutter, cut the hot water copper pipe at this 2-inch mark (Cut A), being as accurate as
possible. Refer to Figure A. Once accomplished, unscrew the original connection fitting from the
outlet thread of the tank.
3. On the now exposed tank outlet thread, screw on the Female NPT Adapter (reference pg. 9), tightly
securing this connection. Wrap the thread 2-3 times with Teflon Tape to seal the connection and
prevent leaks.
4. Now from the in-place Female NPT adapter, measure upwards EXACTLY 11 ⅛ inches. Refer to
Figure B. Mark this on the copper pipe with a pencil. IT IS IMPERATIVE THAT ACCURACY BE USED
DURING THIS STEP. CUTTING THE PIPE TOO MUCH WILL PREVENT A SECURE CONNECTION FROM
TAKING PLACE.
5. Cut the pipe at the 11 ⅛ inch mark (Cut B), taking extreme care for accuracy. If the installer is less
experienced or unsure, it is advised to cut the pipe slightly below the 11 ⅛ inch mark. It is safer to
cut too little and correct a mistake than to cut too much.
6. Secure a Push-to-Connect fitting onto the hanging copper pipe, making sure there are no stray or
jagged pieces of copper stemming from the pipe. Make sure the Push-to-Connect fitting is pushed
as far up as possible onto the copper pipe, fully sealing the connection.
7. Proceed to Plumbing Installation on page 8 with reference guide on page 9.
Hot Water
Copper Pipe
Hot Water Outlet
Connection Fitting
(Can be variety of fittings)
2
Figure A.
Cut A.
11 ⅛”
Figure B.
Cut B.
¾” Female NPT to
⅝” Tube Adapter