Instructions / Assembly

RESETTING THE HIGH LIMIT SWITCH:
For various reasons the high limit safety shut off switch will occasionally
shut the water heater down. This shut down will occur when water tem-
peratures exceed 190F. Power is automatically turned off to the heating
element. The shut off device may activate as a result of a power outage
or an electrical storm.
NOTE: Do not attempt to reset the high limit switch without rst allow-
ing the water heater to cool down the high temperature water inside the
heater.
WARNING: Do not tamper with the reset button to over ride overheating
shut down.
1. Turn off the power switch and unplug the water heater from
the electric outlet.
2. Drain and remove the water heater. (see page 12)
3. Remove six screws retaining the bottom panel of the water heater
and remove the panel. Locate the high limit reset button.
4. Depress the small red button in the center of the junction box,
replace the bottom panel and place the water heater back into
service.
NOTE: A lower temperature setting saves energy and reduces the risk of
scalding.
CAUTION!: Call a technician if the high limit needs to be reset frequently.
High Limit Reset Button
Heating Element
Page 14