3) ELECTRICAL HOOK-UP
Your Eemax heater must have its own independent circuit using
insulated, UL listed, 3 wire cable of the appropriate size suitable
for use up to 75
o
C protected by the correctly rated circuit breaker.
RATINGS OF “EX T ” UNITS
* The heaters are rated at 240 Volts. If the actual voltage supplied is lower
there will be a proportional drop in output.
1) Wire entry into the unit should be made through the lower right hand corner of
the backplate via one of the two “knockout” holes provided.
2) The “mains” wires should be connected to the slots in the terminal block marked
L1 and L2 or N. The ground lead must be connected to the slot marked .
Failure to ground the system may result in death or serious injury.
WARNING
BEFORE BEGINNING ANY WORK ON THE INSTALLATION
BE SURE THAT THE BREAKER IS “OFF”
TO AVOID ANY DANGER OF SHOCK.
FIGURE 2
TO
APPROPRIATE
SIZE
BREAKER
OUTLET VALVE (B)
(ADJUST TO GIVE
APPROXIMATE
DESIRED TEMP.)
INLET VALVE (A)
(FULLY OPEN)
WIRE ENTRY
EITHER THROUGH
REAR OR
BOTTOM
KNOCK-OUTS
MOUNTING HOLES
4 1/4 inches
8 inches
APPROPRIATE
GAUGE 3 LEAD
COPPER WIRE
WARNING:
This water heater must not be switched “on” if there is
a possibility that the water in the heater is frozen.
EX3012T 120 3,000 W 25 40 27 20
EX3512T 120 3,500 W 30 48 31 24
EX35T* 240 3,500 W 15 48 32 24
EX55T* 240 5,500 W 23 75 50 37
EX65T* 240 6,500 W 27 88 59 44
EX75T* 240 7,500 W 31 - 68 51
EX95T* 240 9,500 W 39 - 86 65
EX60T 277 6,000 W 22 81 55 41
EX80T 277 8,000 W 29 - 73 55
EX90T 277 9,000 W 33 - 82 61
EX100T 277 10,000 W 36 - 91 68
EX8208T
208 8,300 W 39 - 76 57
TEMP
ADJ
KNOB
RELAY