Tepid Water Solutions Data Sheet

WWW.EEMAX.COM
EX09001-70 REV 2018-04
EEMAX INC. 400 Captain Neville Drive, Waterbury, CT 06705 Tel. (800) 543-6163 Fax (203) 267-7890
Eyewash and Eye / Face Wash
Temperature Rise (°F)
Volts Model Product Family kW Amps
Turn-On
(GPM)
Recommended
Wire Size (CU)
0.3
GPM
0.75
GPM
1.8
GPM
3.0
GPM
4.0
GPM
120
Single Phase
SPEX2412T EE LavAdvantage 2.4 20 0.2 14 AWG 55 22 9
SPEX3012T EE LavAdvantage 3.0 25 0.2 12 AWG 60† 27 11
SPEX3512T EE LavAdvantage 3.5 29 0.2 10 AWG 60† 32 13 8
240
Single Phase
SPEX35T EE LavAdvantage 3.5 15 0.2 14 AWG 60† 32 13 8
SPEX48T EE LavAdvantage 4.8 20 0.2 14 AWG 60† 44 18 11
SPEX55T EE LavAdvantage 5.5 23 0.2 12 AWG 60† 50 21 13
SPEX65T EE LavAdvantage 6.5 27 0.2 12 AWG 60† 59 25 15
SPEX75T EE LavAdvantage 7.5 32 0.2 10 AWG 60† 60† 28 17
SPEX95T EE LavAdvantage 9.5 40 0.2 8 AWG 60† 60† 36 22
SPEX012240T EE LavAdvantage 11.5 48 0.2 8 AWG 60† 60† 44 26
EX144T2 EE Series Two 15.0 64 1.5 10 AWG 57 34 26
EX190T2 EE Series Two 19.0 80 1.5 8 AWG 60† 43 32
EX023240T2 EE Series Two 23.0 96 1.5 8 AWG 60† 52 39
208
Single Phase
SPEX4208T EE LavAdvantage 4.1 20 0.2 14 AWG 60† 37 16 9
SPEX8208T EE LavAdvantage 8.3 40 0.2 8 AWG 60† 60† 31 19
EX1608T2 EE Series Two 16.6 80 1.5 8 AWG 60† 38 28
277
Single Phase
SPEX3277T EE LavAdvantage 3.0 11 0.2 14 AWG 60† 27 11
SPEX4277T EE LavAdvantage 4.1 15 0.2 14 AWG 60† 37 16 9
SPEX60T EE LavAdvantage 6.0 22 0.2 12 AWG 60† 55 23 14
SPEX80T EE LavAdvantage 8.0 29 0.2 10 AWG 60† 60† 30 18
SPEX90T EE LavAdvantage 9.0 33 0.2 10 AWG 60† 60† 34 20
SPEX100T EE LavAdvantage 10.0 36 0.2 8 AWG 60† 60† 38 23
EX160T2 EE Series Two 16.0 58 1.5 10 AWG 60† 36 27
EX200T2 EE Series Two 20.0 72 1.5 8 AWG 60† 46 34
208
Three Phase
EX180T2T EE Three Phase 18.0 50/phase 0.7 8 AWG 60† 60† 41 31
EX180T3 EE Three Phase 18.0 50/phase 2.0 8 AWG 60† 41 31
EX240T2T EE Three Phase 24.0 67/phase 0.7 4 AWG 60† 60† 55 41
EX240T3 EE Three Phase 24.0 67/phase 2.0 4 AWG 60† 55 41
480
Three Phase
ED020480T3 EE Three Phase 20.0 24/phase 2.0 10 AWG 60† 46 34
ED024480T3 EE Three Phase 24.0 29/phase 2.0 10 AWG 60† 55 41
ED032480T3 EE Three Phase 32.0 38/phase 2.0 8 AWG 60† 60† 55
†Temperature electronically limited to factory preset not to exceed temperature. “–” indicates not operable.
Eye / Face Wash and Drench Shower
Temperature Rise (°F)
Volts Model NEMA 4 Cabinet Sux kW Amps
Turn-On
(GPM)
Recommended
Wire Size (CU)
4.0
GPM
20.0
GPM
23.0
GPM
26.0
GPM
30.0
GPM
208
Three Phase
AP032208 EE N4, N4X 32 89/phase 1.0 3 AWG 55 11 10 8 7
AP036208 EE N4, N4X 36 100/phase 1.0 3 AWG 60† 12 11 9 8
AP041208 EFD N4, N4X 41 113/phase 1.0 2 AWG 60† 14 12 11 9
AP054208 EFD N4, N4X 54 150/phase 1.5 1/0 AWG 60† 18 16 14 12
AP064208 EFD N4, N4X 64 178/phase 2.5 3/0 AWG 60† 22 19 17 15
480
Three Phase
AP036480 EE N4, N4X 36 43/phase 1.0 8 AWG 60† 12 11 9 8
AP039480 EE N4, N4X 39 47/phase 1.0 8 AWG 60† 13 12 10 9
AP048480 EFD N4, N4X 48 58/phase 1.0 6 AWG 60† 16 14 13 11
AP054480 EFD N4, N4X 54 65/phase 1.5 6 AWG 60† 18 16 14 12
AP063480 EFD N4, N4X 63 76/phase 2.5 4 AWG 60† 22 19 17 14
AP072480 EFD N4, N4X 72 87/phase 2.5 3 AWG 60† 25 21 19 16
AP096480 EFD N4, N4X 96 116/phase 2.5 1 AWG 60† 33 29 25 22
AP108480 EFD N4, N4X 108 130/phase 2.5 1 AWG 60† 37 32 28 25
AP126480 EFD N4, N4X 126 151/phase 2.5 2/0 AWG 60† 43 37 33 29
AP144480 EFD N4, N4X 144 173/phase 2.5 2/0 AWG 60† 49 43 38 33
600
Three Phase
AP061600 EFD N4, N4X 61 59/phase 2.5 6 AWG 60† 21 18 16 14
AP071600 EFD N4, N4X 71 68/phase 2.5 4 AWG 60† 24 21 19 16
AP102600 EFD N4, N4X 102 98/phase 2.5 3 AWG 60† 35 30 27 23
AP130600 EFD N4, N4X 130 125/phase 2.5 1 AWG 60† 44 39 34 30
AP150600 EFD N4, N4X 150 144/phase 2.5 1/0 AWG 60† 51 45 39 34
†Temperature electronically limited to factory preset not to exceed temperature.
Sux Denitions
EE Emergency Eyewash. Shipped with
maximum outlet temperature 90°F.
Conforms to ANSI Z3581.1 tepid water
without additional mixing valve.
EFD Emergency Eye, Face & Drench.
Shipped with maximum outlet temperature
90°F. Conforms to ANSI Z3581.1 tepid
water without additional mixing valve.
NEMA 4 Cabinet Options
N4
Waterproof powder coated steel
N4X
Waterproof corrosion resistant
304 stainless steel
N4X6
Waterproof corrosion resistant
316 stainless steel
NEMA 4 Cabinet Option Accessories
FP
Freeze protection (-30°F)
EDS
Non-fused disconnect
FDS
Fused disconnect
EP
Explosion proof (C1D2 compliant)
GFCI
True RMS GFCI with digital display and
reset
SK
24’’ legs for free standing applications
RD
Remote display
SB
Siren and beacon
DC
Dry contact
ES
Emergency stop - push button
Eemax recommends the
use of a NEMA 4 Cabinet
for safety applications. For
additional SafeAdvantage
specifications, view the Eemax
specification guide.
Heaters with 90°F maximum
output should not feed a
thermostatic mixing valve.
If a TMV is required, order
the heater capable of 140°F
output.
For detailed specification information on SafeAdvantage products, consult the Eemax Specification Guide.
Tepid Water Solutions
Tankless Heaters for ANSI Z358.1 Safety
Shower and Emergency Eyewash