Specification Sheet

Information and product specications contained in this document are subject to change without notice. REV 2019-02
Specications
Electric Tankless Water Heater
Series Two
, "T2"
Parallel Models (Two Heating Modules) with Thermostatic Control
Applications
Single high volume xture
Booster (Solar backup)
Commercial/Industrial
Adjustable, precise temperature setting +/–1°F at steady state
(ambient up to 180°F)
Performance Features
Parallel turn on
On demand hot water
Continuous hot water. No storage capacity to run out
Reduces installation cost and material. No T&P relief valve
needed (check local codes) or venting
Easy installation with integral 3/4" NPT ttings
Cut energy waste. Flow switch activates heater only on demand
(no standby heat loss)
Meets ANSI Z358.1 tepid water requirement (EE option)
Two glass reinforced heater bodies and Nichrome elements – a
unique, patented ow path ensures optimum heat transfer and
extended element life
Warranty, ve (5) years limited on leaks, one (1) year parts
Field serviceable replaceable cartridge element
Unit mounts on wall
High temperature limit switch
Optional Features
Emergency eye/face wash ANSI Z358.1 (EE)
Factory set ambient to 180°F (60°F-180°F) (FS)
Sanitation 180°F (S)
N4, N4X (304SS) enclosures
Product Specications
Dimensions: 10.25" x 10.75" x 4.5"
Weight: 10.5 lb
Cover: Enameled steel
Color: White
Element: Dual replacement cartridge inserts.
Thermostatic control (+/-1°F) accuracy at steady
state
Fittings:
3/4" NPT ttings at bottom of unit
Min. Dynamic Operating Pressure: 40 PSI
Max. Dynamic Operating Pressure: 150 PSI
UL Listing: E86887
U.S. Patent #'s: 4,762,980 and 4,960,976
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Suggested Specication
Tankless water heater shall be an Eemax Series Two model
number EX_________________________.
Heater shall have two heating modules. Element shall be
replaceable cartridge insert. Unit shall have a replaceable lter
in the inlet connector. Heater shall be tted with 3/4" NPT water
connections. Maximum operating pressure of 150 PSI. Hot water
storage tanks prohibited. Unit shall be Eemax or approved equal.
NOTE: Refer to rating chart for product information.
Enclosure to be tted with the following features:
_____ EE
Emergency Eyewash. Meets ANSI tepid water
requirements. Max. temperature of 90°F
_____ FS
Factory Set. Customer specied factory-set not to
exceed temperature ambient to 180°F (60°F-180°F)
_____ S
Sanitation. Factory preset not to exceed
temperature of 180°F
_____ N4
NEMA 4 steel cabinet with powder coat nish
_____ N4X NEMA 4 stainless steel, corrosion-resistant cabinet
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
In USA
Assembled