Specification Sheet

Information and product specications contained in this document are subject to change without notice. REV 2020-01
Specications
Tankless Electric Water Heater
Three Phase
Triple Module, Commercial/Industrial Thermostatic 3-Phase Heater
Applications
Eye/face wash
Where tepid water is needed
Multiple lavatories
Restaurants and other food service requirements
Booster applications
Manufacturing and wash down processes
Commercial and industrial
Performance Features
Hot or cold water feed
Available electrical models are 480V Delta (ED models) or 208V
Delta (EX models) no neutral leg required
Fitted with 1/2" compression ttings and electrical entry on the
bottom
Built in over temp protection
Flow switch activates heater only on demand (no standby heat
loss)
Save water – "Point of use application"
Continuous hot water – no storage capacity to run out
Factory set temperature available. Range ambient to 180°F
Capacity to 5 GPM (T3 only), 4 GPM (T2T)
Thermostatic control. Microprocessor provides stable outlet
temperatures
Warranty, ve (5) years limited on leaks, one (1) year parts
Field serviceable replaceable cartridge element
Optional Features
Emergency eye/face wash ANSI Z358.1 (EE)
Factory set ambient to 180°F (FS)
Multi lavs 0.3 turn on. Staged up to 4 lavs 105°F-110°F temp
setting, aerators supplied (ML)
Sanitation 180°F (S)
N4, N4X (304SS) enclosures
Product Specications:
Dimensions: 18.25" x 12.25" x 4.5"
Weight: 15 lb
Cover: Powder Coated Steel
Color: White
Element: Triple replaceable Nichrome cartridge elements
insert
Fittings:
1/2" compression ttings at bottom of unit
Min. Dynamic Operating Pressure: 25 PSI
Max. Dynamic Operating Pressure: 150 PSI
U.S. Patent #'s: 4,762,980 and 4,960,976
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Suggested Specication
Tankless water heater shall be an Eemax "Three Phase" model
number _________________________.
Element shall be replaceable cartridge insert. Element shall be
iron free, Nickel Chrome material. Heater shall be tted with 1/2"
compression ttings. Heater shall be installed upright with water
connections on bottom. Hot water storage tanks prohibited. Unit
shall be Eemax or approved equal.
NOTE: Refer to rating chart for product information.
Enclosure to be tted with the following features:
_____ EE
Emergency Eyewash. Meets ANSI tepid water
requirements
_____ FS
Factory Set. Customer specied factory-set not to
exceed temperature ambient to 180°F
_____ ML
Multi lavs 0.3 GPM turn on, staged up to 4 lavs
105°F-110°F temp setting, aerators supplied
_____ S
Sanitation. Factory preset not to exceed
temperature of 180°F
_____ N4
NEMA 4 steel cabinet with powder coat nish
_____ N4X NEMA 4 stainless steel, corrosion-resistant cabinet
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
In USA
Assembled
L1
L2
L3
Electrical conguration and requirements
All Eemax three phase units are custom made to order and as such, are non-returnable
and non-refundable. Check your electrical supply, making sure all criteria for operating your
Eemax water heater are met.
Eemax 600V, 480V and 208V
Three Phase Units Delta Conguration
Requires: 3 Lives and 1 Ground (earth)

Summary of content (2 pages)