Product Overview
Series Two
Applications
• Single or Multi fixture
• Residential showers
• Commercial/Industrial
• Photo processing
• Adjustable, precise temperature setting +/–1°F (ambient
up to 180°F)
• Solar backup with FS option
Performance Features
• Turns on in stages based on hot water demand
Min. flow 0.7 GPM, max. flow 3 GPM (ML units turn on
0.3 GPM - 110°F max.)
• On demand hot water
• Continuous hot water. No storage capacity to run out
• Reduces installation cost and material. No T&P relief valve
needed (check local codes) or venting
• Easy installation with integral 3/4” NPT fittings
• Cut energy waste. Flow switch activates heater only on
demand (no standby heat loss)
• Reduces calcification
• Two glass-fiber reinforced heater bodies and Ni Chrome
elements – a unique, patented flow path ensures optimum
heat transfer and extended element life
• Warranty – Five (5) years leaks and one (1) year on parts.
Field serviceable replaceable cartridge element, one (1) year
• Unit mounts on wall
• High temperature limit switch
Optional Features
• Factory set ambient to 180°F (FS)
• Multi lavs 0.3 turn on. Staged up to 4 lavs 105°F-110°F temp
setting (ML)
• Sanitation 180°F (S)
• N4, N4X (304SS) enclosures
Product Specifications
Dimensions 10” x 10.5” x 3”
Weight 10.5 lbs.
Cover Enameled steel
Color White
Element Dual replacement cartridge inserts
Thermostatic control (+/-1°F) accuracy
Pipe-Fittings 3/4” NPT fittings at bottom of unit.
Operating Pressure Min. 40 PSI, max. 150 PSI
UL Listing E86887
U.S. Patent #’s: 4,762,980 and 4,960,976
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Series Two, Residential/Commercial “TC”
Staged models (Two heating modules) with thermostatic control
Specifications
Electric Tankless Hot Water Heater
The wetted surface of this product contacted by water
contains less than 0.25% lead and meets ANSI/NSF 372
Suggested Specification
Tankless water heater shall be an Eemax Series Two model
number EX_________________________.
Heater shall have two heating modules. Element shall be
replaceable cartridge insert. Unit shall have a replaceable filter
in the inlet connector. Heater shall be fitted with
3/4” NPT water connections. Maximum operating pressure
of 150 PSI. Hot water storage tanks prohibited. Unit shall be
Eemax or approved equal.
NOTE: Refer to rating chart for product information.
Enclosure to be fitted with the following features:
_____ FS Factory set ambient to 180°F
_____ ML Multi lavs 0.3 turn on. Staged up to
4 lavs 110°F temp setting
_____ S Sanitation 180°F
_____ N4 NEMA 4 waterproof cabinet w/powder coat finish
_____ N4X NEMA 4 stainless steel waterproof corrosion-
resistant cabinet
23
Information and product specifications contained in this document are subject to change without notice.