Product Overview

Series 1
Single Point and
Flow Controlled
12
Information and product specifications contained in this document are subject to change without notice.
Point of Use “Non-Thermostatic”
Single Point and Flow Controlled (Designed for cold water feed only)
Specifications
Electric Tankless Hot Water Heater
TEMPERATURE RISE °F
MODEL NUMBER
kW
AMPS
TURN ON
(GPM)
RECOMMENDED
WIRE SIZE (CU)
0.5
GPM
0.75
GPM
1.0
GPM
1.5
GPM
VOLTS 120
C
SP2412
2.4kW 20A 0.3 12 AWG 33°
C
EX2412
2.4kW 20A 0.3 12 AWG 33°
C
SP3012
3.0kW 25A 0.3 10 AWG 41°
C
EX3012
3.0kW 25A 0.3 10 AWG 41°
C
SP3512
3.5kW 29A 0.3 10 AWG 48°
C
EX3512
3.5kW 29A 0.3 10 AWG 48°
VOLTS 208 Single Phase
C
SP3208
3.0kW 15A 0.3 14 AWG 41°
C
EX3208
3.0kW 15A 0.3 14 AWG 41°
C
SP4208
4.1kW 20A 0.3 12 AWG 56°
C
EX4208
4.1kW 20A 0.3 12 AWG 56°
C
SP8208
8.3kW 40A 0.7 8 AWG 76° 57° 38°
C
SP8208 DL
8.3kW 40A 0.7 8 AWG 76° 57° 38°
C
EX8208
8.3kW 40A 0.7 8 AWG 76° 57° 38°
C
EX8208 DL
8.3kW 40A 0.7 8 AWG 76° 57° 38°
VOLTS 240
*
C
SP35
3.5kW 15A 0.3 14 AWG 48° 32° 24° 16°
C SP35
(derated 208V perf.) 2.7kW 13A 0.3 * 37° 24° 18° 15°
C
EX35
3.5kW 15A 0.3 14 AWG 48° 32° 24° 16°
C EX35 (derated 208V perf.) 2.7kW 13A 0.3 * 37° 24° 18° 15°
C
EX35 SL
3.5kW 15A 0.3 14 AWG 48° 32° 24° 16°
C
SP48
4.8kW 20A 0.5 12 AWG 64° 42° 31° 21°
C SP48
(derated 208V perf.) 3.6kW 17A 0.5 * 49° 33° 25° 16°
C
SP48 DL
4.8kW 20A 0.5 12 AWG 64° 42° 31° 21°
C
EX48
4.8kW 20A 0.5 12 AWG 64° 42° 31° 21°
C EX48 (derated 208V perf.) 3.6kW 17A 0.5 * 49° 33° 25° 16°
C
EX48 SL
4.8kW 20A 0.5 12 AWG 64° 42° 31° 21°
C
EX48 DL
4.8kW 20A 0.5 12 AWG 64° 42° 31° 21°
C
SP55
5.5kW 23A 0.5 10 AWG 75° 50° 38° 25°
C SP55
(derated 208V perf.) 4.1kW 20A 0.5 * 56° 38° 28° 19°
C
SP55 DL
5.5kW 23A 0.5 10 AWG 75° 50° 38° 25°
C
EX55
5.5kW 23A 0.5 10 AWG 75° 50° 38° 25°
C EX55 (derated 208V perf.) 4.1kW 20A 0.5 * 56° 38° 28° 19°
C
EX55 DL
5.5kW 23A 0.5 10 AWG 75° 50° 38° 25°
C
EX55 SL
5.5kW 23A 0.5 10 AWG 75° 50° 38° 25°
C
SP65
6.5kW 27A 0.7 10 AWG 59° 44° 30°
C SP65
(derated 208V perf.) 4.9kW 24A 0.7 * 66° 44° 33° 22°
C
SP65 DL
6.5kW 27A 0.7 10 AWG 59° 44° 30°
C
EX65
6.5kW 27A 0.7 10 AWG 59° 44° 30°
C EX65 (derated 208V perf.) 4.9kW 24A 0.7 * 66° 44° 33° 22°
C
EX65 DL
6.5kW 27A 0.7 10 AWG 59° 44° 30°
C
EX65 SL
6.5kW 27A 0.7 10 AWG 59° 44° 30°
C
SP75
7.5kW 32A 0.7 8 AWG 68° 51° 34°
C SP75
(derated 208V perf.) 5.6kW 27A 0.7 * 77° 51° 38° 26°
C
SP75 DL
7.5kW 32A 0.7 8 AWG 68° 51° 34°
C
EX75
7.5kW 32A 0.7 8 AWG 68° 51° 34°
C EX75 (derated 208V perf.) 5.6kW 27A 0.7 * 77° 51° 38° 26°
C
EX75 DL
7.5kW 32A 0.7 8 AWG 68° 51° 34°
C
EX75 SL
7.5kW 32A 0.7 8 AWG 68° 51° 34°
C
SP95
9.5kW 40A 0.7 8 AWG 87° 65° 43°
C SP95
(derated 208V perf.) 7kW 34A 0.7 * 95° 64° 48° 32°
C
SP95 DL
9.5kW 40A 0.7 8 AWG 87° 65° 43°
C
EX95
9.5kW 40A 0.7 8 AWG 87° 65° 43°
C EX95 (derated 208V perf.) 7kW 34A 0.7 * 95° 64° 48° 32°
C
EX95 DL
9.5kW 40A 0.7 8 AWG 87° 65° 43°
C
EX95 SL
9.5kW 40A 0.7 8 AWG 87° 65° 43°
* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL
standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check
with local officials prior to derating the electrical infrastructure.
3/8” compression fittings at top of unit
“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/
CSA-C22.2 No. 64/No. 88.
2 7/8”
9 3/4”
5 1/4”
10 3/4”
3/4”
1 1/2”
OUTLET INLET
“EX”
9 3/4”10 3/4”
1 1/2”
OUTLET INLET
3/4”
2 7/8”5 1/4”
“SP”
9.67
5.22
1.1
1 1.50
3.00
.81
11.81
9.84
7.30
11.08
1.07 4.17 1.50
5.91
NEMA 4/4X
For EX version only. NEMA cabinets not
available for SP version.
INLETOUTLET
4X Ø.25
MOUNTING
HOLES
9.67
5.22
1.111.50
3.00
.81
INLETOUTLET
INLETOUTLET
Suffix Definitions
DL Dual Lavs – Two faucet aerators provided
SL Single Lav – 3/8” compression connections
TEMPERATURE RISE °F
MODEL NUMBER
kW AMPS
TURN ON
(GPM)
RECOMMENDED
WIRE SIZE (CU)
0.5
GPM
0.75
GPM
1.0
GPM
1.5
GPM
VOLTS 277
SP3277
3.0kW 11A 0.3 14 AWG 41°
EX3277
3.0kW 11A 0.3 14 AWG 41°
SP4277
4.1kW 14.8A 0.3 14 AWG 56° 37° 28° 19°
EX4277
4.1kW 14.8A 0.3 14 AWG 56° 37° 28° 19°
SP60
6.0kW 22A 0.7 10 AWG 55° 41° 27°
SP60 DL
6.0kW 22A 0.7 10 AWG 55° 41° 27°
EX60
6.0kW 22A 0.7 10 AWG 55° 41° 27°
EX60 SL
6.0kW 22A 0.7 10 AWG 55° 41° 27°
EX60 DL
6.0kW 22A 0.7 10 AWG 55° 41° 27°
SP80
8.0kW 29A 0.7 10 AWG 73° 55° 36°
SP80 DL
8.0kW 29A 0.7 10 AWG 73° 55° 36°
EX80
8.0kW 29A 0.7 10 AWG 73° 55° 36°
EX80 SL
8.0kW 29A 0.7 10 AWG 73° 55° 36°
EX80 DL
8.0kW 29A 0.7 10 AWG 73° 55° 36°
SP90
9.0kW 33A 0.7 8 AWG 82° 61° 41°
SP90 DL
9.0kW 33A 0.7 8 AWG 82° 61° 41°
EX90
9.0kW 33A 0.7 8 AWG 82° 61° 41°
EX90 SL
9.0kW 33A 0.7 8 AWG 82° 61° 41°
EX90 DL
9.0kW 33A 0.7 8 AWG 82° 61° 41°
SP100
10kW 36A 0.7 8 AWG 91° 68° 46°
SP100 DL
10kW 36A 0.7 8 AWG 91° 68° 46°
EX100
10kW 36A 0.7 8 AWG 91° 68° 46°
EX100 SL
10kW 36A 0.7 8 AWG 91° 68° 46°
EX100 DL
10kW 36A 0.7 8 AWG 91° 68° 46°