Installation Manual HA008240 - HA011240 - HA013240 Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free compliance.
IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always be followed. Under no circumstances should you attempt to clean, install, inspect, repair, disassemble, or otherwise service this water heater without first shutting off all power to the unit directly at the breaker box. SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.
Part Identification 1. 2. 3. 4. 5. 6. 7. 8. Hot Water Outlet Cold Water Inlet Celsius / Fahrenheit Conversion Setting Temp, Display Power Knob & Temp.
Plumbing This water heater is supplied with 1/2" compression fittings, Do not weld, solder, use Teflon or paste. Connect the cold water supply line to the right hand side. Connect the hot water outlet line to the left hand side. Once both water lines are fastened and secured you must run water through the unit for at least 2 to 3 minutes to flush any air pockets (purging) in the lines. It is recommended that all faucets, showers etc be run.
Electrical Connection The electrical installation is based on the different Models. Unit must be installed to independent double pole breakers as per Model Specs below MODEL REQUIRED BREAKER MAX AMP DRAW AWG Cable HA008240 1 x40AMP* 33 #8 HA011240 1 x50AMP* 46 #6 HA013240 1 x60AMP* 54 #6 *Double Pole Check all wires to make sure they are securely fastened and tightened. Before turning the power on make sure the system has been purged as required in the plumbing section.
How to use the knob Power •Click the power knob, the unit will turn on •Click the power knob again, the unit will turn off °C/F Conversion •Press the knob for 3 seconds, the display will change Temperature Control •Turning it clock wise increases the temperature setting •Turning it counter-clockwise will decrease the temperature setting You can set or adjust your temperature at any time between 80°F-140°F (4.4°C 60°C) The temperature can be changed to your desired setting.
VERIFY ALL VOLTAGE & AMPERAGE INFO LISTED BELOW, WITH THE ACTUAL LABEL SPECIFICATIONS ON YOUR UNIT, FOR ANY CHANGES OR VARIATIONS MODEL KW VOLTS AMPS BATHS FLOW RATE IN GALLONS PER RISE IN WATER TEMP HA008240 8KW 240V 33 1 1.5 36 HA011240 11KW 240V 46 1 1.5 50 HA013240 13KW 240v 54 1 1.5 60 GAUGE AND BREAKER SIZE CAN VARY BASED ON A NUMBER OF FACTORS INCLUDING SUPPLIED VOLTAGE AND LENGTH OF CIRCUIT CHECK LOCAL REQUIREMENTS.
Eemax Inc. 400 Captain Neville Drive, Waterbury, CT 06705 TOLL FREE: 800-543-6163. TELEPHONE: 203-267-7890 FAX: 203-267-7975 e-mail: info@eemaxinc.com www.eemax.