Specification Sheet

Information and product specications contained in this document are subject to change without notice. REV 2019-02
Specications
Electric Tankless Water Heater
HomeAdvantage II
For Single Point-of-Use or Multiple Applications
TEMPERATURE RISE °F
MODEL NUMBER kW AMPS
RECOMMENDED
WIRE SIZE
(75° C/CU)
TURN ON
(GPM)
MAX FLOW
(GPM)
0.5
GPM
1.0
GPM
1.5
GPM
2.0
GPM
2.5
GPM
3.0
GPM
4.0
GPM
5.0
GPM
6.0
GPM
VOLTS 240*
C
HA008240
8.0 33(1x40) 8 AWG 0.3 4.8 109° 55° 36° 27° 22° 18° 14°
C
HA008240 (derated 208V performance)
5.8 28 8 AWG 0.3 4.8 79° 40° 26° 20° 16° 13° 10°
C
HA011240
11.0 46(1x50) 8 AWG 0.3 4.8 75° 50° 38° 30° 25° 19°
C
HA011240 (derated 208V performance)
8.2 40 8 AWG 0.3 4.8 56° 37° 28° 22° 19° 14°
C
HA013240
13.0 54(1x60) 6 AWG 0.3 4.8 89° 59° 44° 36° 30° 22°
C
HA013240 (derated 208V performance)
10.1 49(1x60) 6 AWG 0.3 4.8 69° 46° 34° 28° 23° 17°
C
HA018240
18.0 75(2x38) 8 AWG 0.3 7.0 82° 61° 49° 41° 31° 25° 20°
C
HA018240 (derated 208V performance)
13.3 64(2x32) 8 AWG 0.3 7.0 91° 61° 45° 36° 30° 23° 18° 15°
C
HA024240
24.0 100(3x33) 8 AWG 0.3 7.0 109° 82° 66° 55° 41° 33° 27°
C
HA024240 (derated 208V performance)
17.5 84(3x28) 8 AWG 0.3 7.0 80° 60° 48° 40° 30° 24° 20°
C
HA027240
27.0 113(3x37) 8 AWG 0.3 7.0 92° 74° 61° 46° 37° 31°
C
HA027240 (derated 208V performance)
20.0 96(3x32) 8 AWG 0.3 7.0 91° 68° 55° 46° 34° 27° 23°
C
HA036240
36.0 150(4x38) 8 AWG 0.3 8.0 98° 82° 61° 49° 41°
C
HA036240 (derated 208V performance)
26.6 127(4x32) 8 AWG 0.3 8.0 91° 73° 61° 45° 36° 30°
Product
Dynamic Operating Pressure: 25 PSI min., 150 PSI max.
Specications
Certications: ETL Listed to UL 499 and CSA
(all models)
Adj. Temperature Range: 80°F-140°F
Temperature Accuracy: +/–1° at steady state
* 240V units can be used on 208V
single phase with 25% reduced
temperature output. Please note
per UL standards the rating plate
and installation instructions will all
be according to a 240V applied
voltage. Check with local ofcials
prior to derating the electrical
infrastructure.
Temperature electronically limited
setting on adjustable thermostat
on front cover
"C "indicates evaluation and
compliance to either Underwriters
Laboratories (UL) or Intertek
(ETL) under CAN/CSA-C22.2 No.
64/No. 88.
HA024240/HA027240
Size:
17"H x 17"W x 3.75"D
Weight:
13.75 lb
Unique Features:
Welded exchanger, 3/4" NPT ttings
HA036240
Size:
17"H x 21"W x 3.75"D
Weight:
17.4 lb
Unique Features:
Welded exchanger, 3/4" NPT ttings
5.9
17.0
3.4 17.0
16.0
2.8
1.4
15.1
9.8
17.0
3.4 20.8
19.8
15.1
3.2
1.5
15.1
5.9
17.0
3.4 13.9
12.9
1.6
1.5
HA008240/HA011240/HA013240
Size:
11.5"H 8"W x 3.75"D
Weight:
8 kw: 4.75 lb, 11 kw/13 kw: 7 lb
Unique Features:
Welded exchanger, 1/2" compression ttings with 1/2" NPT
adapters included
HA018240
Size: 17"H x 14"W x 3.75"D
Weight:
11.25 lb
Unique Features:
Welded exchanger, 3/4" NPT ttings
9.9
7.9
11.4
12.2
1.9
8.8
3.4
4.1