Product Overview

Series 1
Single Point and
Flow Controlled
11
Information and product specifications contained in this document are subject to change without notice.
Applications
• Hand washing (0.35-2.0 GPM)
Kitchen/bar/utility sinks
Manufacturing facilities
Hand set shower (0.7-2.0 GPM)
Dual handwash sinks (DL option)
Modular buildings and tenant spaces
Performance Features
On demand hot water. Flow switch activates heater only on
demand (no standby heat loss). 99% efficient
Endless hot water – no storage capacity to run out
Easy installation. No T&P relief valve needed (check local
codes). Only one cold water line need be brought to
installation, mounts on wall
High temperature limit switch with automatic reset
Optional flow restricting aerator (for EX-DL models) ensures
proper temperature rise. Standard with SP models
Prevents Legionella bacteria growth
Reduces calcification, liming and sedimentation
Complies with handicap ADA physical installation
requirements
Ni Chrome element – a unique, patented flow path ensures
optimum heat transfer and extended element life
Warranty – Heaters, against failure due to leaks of “Heater
Body/Element Assembly”, five (5) years – Parts, one (1) year
Product Specifications
Dimensions: 10.75” x 5.25” x 2.78”
Weight: 4 lbs.
Cover: ABS UL rated 94V0.
Color: White
Element: Replaceable cartridge insert
Fittings: SP – 3/8” compression fitting at top of unit
EX – 1/2” (5/8” OD) compression fitting at bottom of unit
Operating Pressure: Min. 25 PSI, max. 150 PSI
UL listed file number: E86887
U.S. Patent #’s: 4,762,980 and 4,960,976
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Point of Use “Non-Thermostatic”
Single Point and Flow Controlled (Designed for cold water feed only)
Specifications
Electric Tankless Hot Water Heater
The wetted surface of this product contacted by water
contains less than 0.25% lead and meets ANSI/NSF 372
Pictured, EX: Bottom Water Connections
U.S. Patent #’s: 4,762,980 and 4,960,976
EX Version
1/2”
compression
fittings at
BOTTOM
of unit
SP Version
3/8”
compression
fittings at TOP
of unit
Suggested Specification
Tankless water heater shall be an Eemax Non-Thermostatic
model number ___________.
Unit shall have ABS-UL 94V0 rated cover. Element shall be
replaceable cartridge insert. Unit shall have replaceable filter in
the inlet connector. Element shall be iron free, nickel chrome
material. Water heater to be supplied with compression fittings.
EX models will have 1/2 fittings on the bottom of unit, SP units
to have 3/8’’ fittings on the top of unit. Maximum operating
pressure of 150 PSI. Hot water storage tanks prohibited. Unit
shall be Eemax or approved equal. NOTE: Refer to rating chart
for product information.
Specification options available on EX models:
_____ DL Dual Lavs- supplied with two faucet aerators
_____ SL Single Lav – supplied with 3/8’’ compression
fittings (0.5 or 1.0 GPM aerator included).
_____ N4 NEMA 4 waterproof cabinet w/powder coat finish
_____ N4X NEMA 4 stainless steel waterproof corrosion-
resistant cabinet

Summary of content (2 pages)