Use and Care Manual
STEP THREE:
In the brass outlet fitting there is a flow restrictor
This is a little black bung. Shut the water off to the unit and then
remove the bung from the fitting. Now replace the fitting and with the
faucet open fully see if the light comes on now, with water flowing
through the unit.
PAGE FOUR
0.5 gpm flow regulator
(The little black bung)
INLET
OUTLET
SP MODELS
UP
inlet filter
4
If the heater now turns “on” with water flowing, call Eemax at 1-800-543-6163.
Describe what you have done and we will send you a selection of “bungs” to replace
the one which you have removed. This will allow the unit to turn “on” but will also
control the flow rate to give you the correct rise in temperature.
If the heater still does not work proceed to step 4.