Use and Care Manual

PAGE FIVE
V
A
STEP FOUR:
You will require a multimeter / voltmeter to
carry out the next tests.
DANGER!
TURN OFF THE BREAKER BEFORE PROCEEDING WITH
THE NEXT TESTS
Set the meter to the single Ohms setting
Do not
measure continuity this will not work.
The Ohm symbol
(The upside down horse shoe)
Remove the heater cover, at the end of the black heater body there are two threaded
silver rods with brass nuts on them. (where the wires go). Take a reading of the ohms
value between these two rods.
5
If the reading is less than 20 ohms on
the “Rx 1” scale or the “Rx 10” scale
the element is good, if it is much
greater e.g.... 10,000 ohms or if you get a
reading on the “Rx 1K” scale then you
must replace the element (contact Eemax).
Tel : 1-800-543-6163 for replacement
elements.