Use and Care Manual
PAGE SEVEN
Other possible solutions:
STEP ONE:
Make sure the printed circuit board is mounted in the correct position. This
is the top set of mounting holes. (see diagram below). Failure to mount the board in the
correct position will cause element burn out and may cause further damage to your
heater. (This board may have been incorrectly moved when serviced previously.)
The correct mounting holes
for the PCB on an “SP” model.
STEP TWO
Inspect the inlet filter (see diagram on page four for location). Make sure
it is free from debris, pipe dope or anything else which may hinder water flow.
IF HAVING CARRIED OUT ALL THE TESTS LISTED ABOVE YOUR HEATER
IS STILL NOT FUNCTIONING PLEASE CALL THE TECHNICAL SUPPORT LINE
AT EEMAX : 1-800-543-6163
PLEASE HAVE THE FOLLOWING INFORMATION AVAILABLE :
1) ORDER REF. NUMBER ( on U.L. rating label on the front cover of unit.)
2) SERIAL NUMBER (inside unit on backplate)
7
Board mounted in correct
position