INSTALLATION GUIDE AND OWNER’S MANUAL LavAdvantage ELECTRIC INSTANTANEOUS WATER HEATERS
BEFORE ATTEMPTING ANY INSTALLATION, MODIFICATION OR SERVICE OF THIS HEATER, MAKE SURE THE ELECTRICAL POWER IS DISCONNECTED. Read and understand these instructions thoroughly before attempting the installation or service of this water heater. Failure to follow these instructions can result in serious injury, death and/or property damage. The warranty of this water heater will depend upon the proper installation according to these instructions. Some heaters come supplied with separate faucet aerators.
(CANADIAN INSTALLATIONS ONLY) CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER. ATTENTION: BRANCHER UNIQUEMENT À UN CIRCUIT PROTÉGÉ PAR UN DISJONCTEUR DE FUITE DE TERRE DE CLASSE A. (CANADIAN INSTALLATIONS ONLY) DO NOT INSTALL IN A BATH ENCLOSURE OR SHOWER STALL OR CONNECT TO A SALT-REGENERATED WATER SOFTENER OR A WATER SUPPLY OF SALT WATER.
1) MOUNTING THE UNIT TO THE WALL THIS HEATER MUST BE INSTALLED IN A LOCATION WHERE IT IS NOT SUBJECT TO FREEZING TEMPERATURES. 1. The heater should be mounted “under the sink” as close to the point of use as possible. Ideal position is fittings pointed down, but the heater can be mounted in any orientation 2. Make sure to leave a minimum of 8 inches service 3. Remove the cover and fasten to the wall using the clearance at the end OPPOSITE the fittings.
2) PLUMBING HOOK-UP The heater is supplied with brass 3/8” compression fittings that are compatible with either stainless steel flex hose, copper or plastic pipe. Make sure these fittings are used for this installation. Contact your Eemax representative for further information. NEVER SUBSTITUTE THREADED PIPE FITTINGS USING PIPE DOPE OR TEFLON TAPE AND NEVER SOLDER ANY PIPE CONNECTIONS WHILE ATTACHED TO THIS HEATER BECAUSE DAMAGE TO THE HEATER WILL RESULT.
3. Remove the cover. Connect the pre-assembled inlet and outlet pipes to the heater and fully open the inlet and outlet ball valves. Check for water leaks. If a leak is at a compression fitting, slowly tighten the compression nut until it stops. Replace the cover. 4. Open the hot water faucet and run water for minimum 60 seconds and until the flow is continuous and free of air pockets. Close the faucet and install the aerator (if supplied).
3) ELECTRICAL HOOK-UP BEFORE BEGINNING ANY WORK ON THIS INSTALLATION, BE SURE THAT THE ELECTRICAL BREAKER IS “OFF” AND THAT ALL MOUNTING AND PLUMBING WORK HAS BEEN COMPLETED PER THESE INSTRUCTIONS. This heater must have its own independent circuit using insulated, UL listed, 2 wire cable (2 wire plus ground) of the appropriate size suitable for up to 75°C and protected by the correctly rated circuit breaker.
2. The power leads are to be secured to the L1 and L2 or L and N connectors on the terminal block or relay. The ground lead is to be secured to the GND connector on the block or the green ground wire with the provided wire nut. FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY, DEATH AND/OR PROPERTY DAMAGE. 3. Leave the breaker in the “OFF” position.
3. Keep water flowing through the faucet for the next step. 4. For 60 seconds after “power ON”, display will countdown from 60 seconds to 0. When the display timer reaches 45, the unit starts heating. 5. After the 60 seconds in step 4, the display will show temperature setpoint. The heater is considered commissioned at this point. Faucet can be turned off and used as needed. Note: the temperature display will turn off after 5 minutes of inactivity.
5) UNIT OPERATION Remove screw to access user interface Using the Eemax LavAdvantage Control Functions Using the Eemax LavAdvantage is EASY. There are only 2 buttons: “–“and “+”. Moving through the functions requires a minimum of effort – just follow along! During operation the unit will show the current set point temperature and will display this temperature for 5 minutes after the unit is active. Factory temperature setpoints: - Standard heaters, S models: 120°F Units 3.
POWER FACTOR (how hard the heater is ‘working’ shown as a percentage) SOFTWARE REVISION (For Eemax Technical Service use only) Pressing both “+” and “–“ at any time for 3 seconds returns the display to the temperature set point, or just let the heater return to set point display on its own (30 seconds timeout). ERROR CODES & UNITS From Advanced Menu, press and hold the “+” and “–“ buttons for 10 seconds. CURRENT ERROR will display. F0 displays if no errors.
BASIC TROUBLESHOOTING Fault Code Fault name Possible causes Possible Outcome Reset method - heater stops until the fault is cleared - causing condition disappears No heat - element burned out - ECO tripped/malfunctioning - interrupted triac - relay/contactor malfunctioning - board failure - inlet thermistor interrupted F24 Low heat - severe undervoltage - triac failure - partial board failure - partial inlet/outlet thermistors failure - heater keeps running - manual fault clear or while displayi
PERIODIC MAINTENANCE This heater is designed for many years of care free use. In order to maintain consistent water flow, it may be necessary to periodically clean the faucet aerator or the filter screen located in the brass inlet fitting at the heater. Heating chamber Triacs Energy cut-off (ECO) Control board Contactor ELEMENT CARTRIDGE (pictured below) INSTALLS INSIDE HEATING CHAMBER PART NUMBERS FOR FITTINGS, AERATORS AND AERATOR ADAPTORS COMPRESSION FITTINGS: 3/8" NUT 3/8" SLEEVE AERATORS: 0.
REPAIR PARTS FOR “THERMOSTATIC” UNITS Model number Element cartridge SPEX1812T SPEX2412T SPEX3012T SPEX3512T SPEX3208T SPEX4208T SPEX8208T SPEX35T SPEX48T SPEX55T SPEX65T SPEX75T SPEX95T SPEX012240T SPEX3277T SPEX4277T SPEX60T SPEX80T SPEX90T SPEX100T Control board Relay EX800 PRT EX384-120 EX259B EX610 EX384-120 EX259B EX480 EX384-120 EX259B EX410 EX384-120 EX259B EX1440 EX384-240 EX255B EX1050 EX384-240 EX255B EX520 EX384-240 EX255B EX1650 EX384-240 EX255B EX1200 EX384-240 EX255B EX1050 EX384-240 EX2
Notes: Eemax Inc., 400 Captain Neville Drive, Waterbury, CT 06705 Tel: 800-543-6163, 203-267-7890, Fax: 203-267-7975, email: support@eemaxinc.