INSTALLATION GUIDE AND OWNER’S MANUAL LavAdvantage™ ELECTRIC INSTANTANEOUS WATER HEATERS
BEFORE ATTEMPTING ANY INSTALLATION, MODIFICATION OR SERVICE OF THIS HEATER, MAKE SURE THE ELECTRICAL POWER IS DISCONNECTED. Read and understand these instructions thoroughly before attempting the installation or service of this water heater. Failure to follow these instructions can result in serious injury, death and/or property damage. The warranty of this water heater will depend upon the proper installation according to these instructions. Some heaters come supplied with separate faucet aerators.
(CANADIAN INSTALLATIONS ONLY) CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER. ATTENTION: BRANCHER UNIQUEMENT À UN CIRCUIT PROTÉGÉ PAR UN DISJONCTEUR DE FUITE DE TERRE DE CLASSE A. (CANADIAN INSTALLATIONS ONLY) DO NOT INSTALL IN A BATH ENCLOSURE OR SHOWER STALL OR CONNECT TO A SALT-REGENERATED WATER SOFTENER OR A WATER SUPPLY OF SALT WATER.
1) MOUNTING THE UNIT TO THE WALL THIS HEATER MUST BE INSTALLED IN A LOCATION WHERE IT IS NOT SUBJECT TO FREEZING TEMPERATURES. 1. The heater should be mounted under the sink as close to the point-of-use as possible. Ideal position is fittings pointed down, but the heater can be mounted in any orientation. Note: an additional logo decal has been provided to ensure branding is clearly displayed in any mounting orientation. Decal here 2. Make sure to leave a minimum of 8 inches service 3.
2) PLUMBING HOOK-UP The heater is supplied with brass 3/8” compression fittings that are compatible with either copper or plastic pipes. Make sure these fittings are used for this installation. Contact your Eemax representative for further information. NEVER SUBSTITUTE THREADED PIPE FITTINGS USING PIPE DOPE OR TEFLON TAPE AND NEVER SOLDER ANY PIPE CONNECTIONS WHILE ATTACHED TO THIS HEATER BECAUSE DAMAGE TO THE HEATER WILL RESULT.
3. Remove the cover. Connect the pre-assembled inlet and outlet pipes to the heater (do not overtighten compression fittings) and fully open the inlet and outlet ball valves. Check the system for water leaks at all plumbing connections. If a leak is present at the compression fitting, slowly tighten compression nut until it stops – do not overtighten. 4. Open the hot water faucet and run water for minimum 60 seconds and until the flow is continuous and free of air pockets.
3) ELECTRICAL HOOK-UP BEFORE BEGINNING ANY WORK ON THIS INSTALLATION, BE SURE THAT THE ELECTRICAL BREAKER IS “OFF” AND THAT ALL MOUNTING AND PLUMBING WORK HAS BEEN COMPLETED PER THESE INSTRUCTIONS. This heater must have its own independent circuit using insulated, UL listed, 2 wire cable (2 wire plus ground) of the appropriate size suitable for up to 75°C and protected by the correctly rated circuit breaker.
2. The power leads are to be secured to the L1 and L2 or L and N connectors on the terminal block or relay. The ground lead is to be secured to the GND connector on the block or the green ground wire with the provided wire nut. FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY, DEATH AND/OR PROPERTY DAMAGE. 3. Leave the breaker in the “OFF” position.
3. Keep water flowing through the faucet for the next step. 4. The display on the circuit board should come “ON”. With the flow running, the heater will go through the 60 seconds SafeStart™/self-calibration procedure. The display will count down from 60 to 0. When the display timer reaches 45, the unit starts heating and continues counting down to 0. 5. After the 60 seconds in step 4, the display will show the temperature setpoint. The heater is commissioned at this point.
5) UNIT OPERATION Remove screw to access user interface Using the Eemax LavAdvantage Control Functions Using the Eemax LavAdvantage is EASY. There are only 2 buttons: “–“and “+”. Moving through the functions requires a minimum of effort – just follow along! During operation the unit will show the current setpoint temperature and will display this temperature for 5 minutes after the unit is active. Factory temperature setpoints/maximum adjustable range: - Standard models: 120°F (70°F to 140°F) o Units 3.
OUTLET TEMPERATURE (hot water temperature) (°F or °C) POWER FACTOR (how hard the heater is ‘working’ shown as a percentage) SOFTWARE REVISION (For Eemax Technical Service use only) Pressing both “+” and “–“ at any time for 3 seconds returns the display to the temperature set point, or just let the heater return to set point display on its own (120 seconds timeout). ERROR CODES & UNITS From Advanced Menu, press and hold the “+” and “–“ buttons for 10 seconds. CURRENT ERROR will display.
Temp. and flow rate are displayed in the chosen unit setting Error Codes & Units Menu Click + to cycle through parameter Hold + for 1s to cycle through menu Hold – to decrease temp. faster Advanced Menu Click + to cycle through menu Hold – to view parameter name Temperature Setpoint – SET Click + to increase temp. Click – to decrease temp. Hold + to increase temp. faster Hold – to decrease temp.
6) TROUBLESHOOTING CAUTION: Make certain power to unit is “OFF” before removing protective cover FOR ANY REASON. For status code details, please consult the table below. Code Name Possible causes Heater response F23 No heat - element failure - ECO tripped/malfunctioning - triac(s) failed open - relay/contactor malfunctioning - control board failure - inlet water supply out of spec Heating will be disabled after - measure element 30 seconds of continuous no resistance with the unit heat condition.
Default parameters: Status code Model suffix F33 T, ML EE S F47 T, ML, EE, S Default values Trip Reactivation Trip Reactivation Trip Reactivation 170°F 140°F 100°F 95°F 195°F 165°F 65°F 7) PERIODIC MAINTENANCE This heater is designed for many years of care free use. In order to maintain consistent water flow, it may be necessary to periodically clean the faucet aerator or the filter screen located in the brass inlet fitting at the heater.
8) PART NUMBERS FOR FITTINGS, AERATORS AND AERATOR ADAPTORS COMPRESSION FITTINGS: 3/8" NUT EX68B 3/8" SLEEVE EX68C AERATORS: 0.35 GPM EX0061-0.
Notes: Eemax Inc., 400 Captain Neville Drive, Waterbury, CT 06705 Tel: 800-543-6163, 203-267-7890, Fax: 203-267-7975, email: support@eemaxinc.